Determination of patient setup error in radiotherapy using feature-based multimodal rigid image registration

Aayesha Hakim, K. Talele, R. Harsh, Dharmesh Verma
{"title":"Determination of patient setup error in radiotherapy using feature-based multimodal rigid image registration","authors":"Aayesha Hakim, K. Talele, R. Harsh, Dharmesh Verma","doi":"10.1109/IBSS.2015.7456629","DOIUrl":null,"url":null,"abstract":"Accurate patient positioning is one of the major requirements of delivering precise radiation therapy. The objective of this research is to verify the localisation of the dose delivered. In this paper, image registration technique based on anatomical landmarks of the patient is used to compare the similarity between Digitally Reconstructed Radiograph (DRR) and the digital portal image acquired by Electronic Portal Imaging Device (EPID) and calculation of the setup error for pelvic region using bony landmark points is done. The purpose of this study is to evaluate these registration results on the basis of parameters like mutual information, joint histogram, scatter plot, joint entropy, histogram error, line intensity profile and Structural Similarity Index (SSIM). For the pelvis case, the average Euclidean distance by gold standard is less than 2 mm. Our results were satisfactory and within acceptable limits i.e. the maximum set up error obtained is 1.859 mm.","PeriodicalId":317804,"journal":{"name":"2015 IEEE Bombay Section Symposium (IBSS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Bombay Section Symposium (IBSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBSS.2015.7456629","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate patient positioning is one of the major requirements of delivering precise radiation therapy. The objective of this research is to verify the localisation of the dose delivered. In this paper, image registration technique based on anatomical landmarks of the patient is used to compare the similarity between Digitally Reconstructed Radiograph (DRR) and the digital portal image acquired by Electronic Portal Imaging Device (EPID) and calculation of the setup error for pelvic region using bony landmark points is done. The purpose of this study is to evaluate these registration results on the basis of parameters like mutual information, joint histogram, scatter plot, joint entropy, histogram error, line intensity profile and Structural Similarity Index (SSIM). For the pelvis case, the average Euclidean distance by gold standard is less than 2 mm. Our results were satisfactory and within acceptable limits i.e. the maximum set up error obtained is 1.859 mm.
基于特征的多模态刚性图像配准确定放疗患者设置误差
准确的病人定位是提供精确放射治疗的主要要求之一。这项研究的目的是验证所给剂量的局部。本文采用基于患者解剖标志的图像配准技术,比较数字重建x线片(DRR)与电子门静脉成像设备(EPID)获取的数字门静脉图像的相似度,并利用骨标志点计算骨盆区域的设置误差。本研究的目的是根据互信息、联合直方图、散点图、联合熵、直方图误差、线强度剖面和结构相似指数(SSIM)等参数对这些配准结果进行评价。对于骨盆,平均欧氏距离在金标准下小于2mm。我们的结果令人满意,并且在可接受的范围内,即获得的最大设置误差为1.859 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信