{"title":"System optimization for energy measurements of EUV radiation pulses","authors":"J. Mikołajczyk, Z. Bielecki","doi":"10.1109/EURCON.2007.4400587","DOIUrl":null,"url":null,"abstract":"The paper presents a detection system for energy measurement of extreme ultraviolet radiation (EUV). The system consists of a calibrated silicon photodiode and a single multilayer mirror. It can be used for energy measurements of radiation pulses at 13.5 plusmn 0.5 nm wavelength range (FWHM = 7.3%). A construction of the system was optimized for operation with a laser-plasma source with gas puff target. The system provides energy measurements with uncertainty of 7.2%. Influence of particular system elements on uncertainty of the energy measurement.","PeriodicalId":191423,"journal":{"name":"EUROCON 2007 - The International Conference on \"Computer as a Tool\"","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EUROCON 2007 - The International Conference on \"Computer as a Tool\"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EURCON.2007.4400587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper presents a detection system for energy measurement of extreme ultraviolet radiation (EUV). The system consists of a calibrated silicon photodiode and a single multilayer mirror. It can be used for energy measurements of radiation pulses at 13.5 plusmn 0.5 nm wavelength range (FWHM = 7.3%). A construction of the system was optimized for operation with a laser-plasma source with gas puff target. The system provides energy measurements with uncertainty of 7.2%. Influence of particular system elements on uncertainty of the energy measurement.
EUV辐射脉冲能量测量系统优化
介绍了一种用于极紫外辐射能量测量的检测系统。该系统由一个经过校准的硅光电二极管和一个单层多层反射镜组成。它可用于13.5±0.5 nm波长范围(FWHM = 7.3%)的辐射脉冲能量测量。对系统的结构进行了优化,以适应带气体喷涌靶的激光等离子体源的工作。该系统提供的能量测量不确定度为7.2%。特定系统要素对能量测量不确定度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信