Radioimmunoassay with heterologous antibody (hetero-antibody RIA): utilization of highly cross-reactive antibody present in polyclonal antiserum.

A Iwasawa, H Hayashi, Z Itoh, K Wakabayashi
{"title":"Radioimmunoassay with heterologous antibody (hetero-antibody RIA): utilization of highly cross-reactive antibody present in polyclonal antiserum.","authors":"A Iwasawa,&nbsp;H Hayashi,&nbsp;Z Itoh,&nbsp;K Wakabayashi","doi":"10.1507/endocrj1954.38.673","DOIUrl":null,"url":null,"abstract":"<p><p>To develop a homologous radioimmunoassay (RIA) for a hormone of a small or rare animal often meets difficulty in collecting a large amount of purified antigen required for antibody production. On the other hand, to employ a heterologous RIA to estimate the hormone often gives poor sensitivity. To overcome this difficulty, a \"hetero-antibody\" RIA was studied. In a hetero-antibody RIA system, a purified preparation of a hormone is used for radioiodination and standardization and a heterologous antibody to the hormone is used for the first antibody. Canine motilin and rat LH were selected as examples, and anti-porcine motilin and anti-hCG, anti-hCG beta or anti-ovine LH beta was used as the heterologous antibody. The sensitivities of the hetero-antibody RIAs were much higher than those of heterologous RIAs in any case, showing that these hetero-antibody RIA systems were suitable for practical use. To clarify the principle of hetero-antibody RIA, antiserum to porcine motilin was fractionated on an affinity column where canine motilin was immobilized. The fraction bound had greater constants of affinity with both porcine and canine motilins than the rest of the antibody fractions. This fraction also reacted with a synthetic peptide corresponding to the C-terminal sequence common to porcine and canine motilins in a competitive binding test with labeled canine motilin. These results suggest that an antibody population having high affinity and cross-reactivity is present in polyclonal antiserum and indicate that the population can be used in hetero-antibody RIA at an appropriate concentration.</p>","PeriodicalId":11534,"journal":{"name":"Endocrinologia japonica","volume":"38 6","pages":"673-81"},"PeriodicalIF":0.0000,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1507/endocrj1954.38.673","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endocrinologia japonica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1507/endocrj1954.38.673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

To develop a homologous radioimmunoassay (RIA) for a hormone of a small or rare animal often meets difficulty in collecting a large amount of purified antigen required for antibody production. On the other hand, to employ a heterologous RIA to estimate the hormone often gives poor sensitivity. To overcome this difficulty, a "hetero-antibody" RIA was studied. In a hetero-antibody RIA system, a purified preparation of a hormone is used for radioiodination and standardization and a heterologous antibody to the hormone is used for the first antibody. Canine motilin and rat LH were selected as examples, and anti-porcine motilin and anti-hCG, anti-hCG beta or anti-ovine LH beta was used as the heterologous antibody. The sensitivities of the hetero-antibody RIAs were much higher than those of heterologous RIAs in any case, showing that these hetero-antibody RIA systems were suitable for practical use. To clarify the principle of hetero-antibody RIA, antiserum to porcine motilin was fractionated on an affinity column where canine motilin was immobilized. The fraction bound had greater constants of affinity with both porcine and canine motilins than the rest of the antibody fractions. This fraction also reacted with a synthetic peptide corresponding to the C-terminal sequence common to porcine and canine motilins in a competitive binding test with labeled canine motilin. These results suggest that an antibody population having high affinity and cross-reactivity is present in polyclonal antiserum and indicate that the population can be used in hetero-antibody RIA at an appropriate concentration.

异源抗体放射免疫测定(hetero-antibody RIA):利用多克隆抗血清中存在的高交叉反应抗体。
在对小型或稀有动物的激素进行同源放射免疫测定(RIA)时,往往难以收集到生产抗体所需的大量纯化抗原。另一方面,采用异源RIA来估计激素往往灵敏度较差。为了克服这一困难,研究了一种“异抗体”RIA。在异抗体RIA系统中,激素的纯化制剂用于放射碘化和标准化,激素的异源抗体用于第一抗体。以犬胃动素和大鼠LH为例,以抗猪胃动素和抗hcg、抗hcg β或抗羊LH β为异源抗体。在任何情况下,异种抗体RIA系统的灵敏度都远高于异种RIA系统,表明这些异种抗体RIA系统适合实际应用。为了阐明异抗体RIA的原理,将猪胃动素抗血清在固定犬胃动素的亲和柱上分离。与其他抗体片段相比,该片段界与猪和犬的运动素具有更大的亲和力常数。在竞争性结合试验中,该部分还与猪和犬运动素共同的c端序列对应的合成肽反应。这些结果表明,在多克隆抗血清中存在一个具有高亲和力和交叉反应性的抗体群体,表明该群体可以在适当的浓度下用于异抗体RIA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信