J. Remolina, H. Zepeda, J. Miranda, J. Rosas, H. Nohe
{"title":"ASIC for a system for clinical objective evaluation of induced pharmacological neuromuscular blockage","authors":"J. Remolina, H. Zepeda, J. Miranda, J. Rosas, H. Nohe","doi":"10.1109/MMICA.1999.833632","DOIUrl":null,"url":null,"abstract":"Except for the output transistor, and the force transducer, the Application Special Integrated Circuit (ASIC) described herein contains all the electronic components of a system for the objective clinical evaluation of the neuromuscular blockage produced in patients, for medical purposes, by the intravenous injection of muscle relaxing drugs. The system contains three sections: an electric stimulator for motor nerves; a section that receives the signals coming from a force transducer attached to the corresponding muscle, evaluates the relative strength of the ensuing muscular contractions and stores the results in four registers, and a section that drives a liquid crystal display.","PeriodicalId":221297,"journal":{"name":"Proceedings of the Third International Workshop on Design of Mixed-Mode Integrated Circuits and Applications (Cat. No.99EX303)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Third International Workshop on Design of Mixed-Mode Integrated Circuits and Applications (Cat. No.99EX303)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMICA.1999.833632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Except for the output transistor, and the force transducer, the Application Special Integrated Circuit (ASIC) described herein contains all the electronic components of a system for the objective clinical evaluation of the neuromuscular blockage produced in patients, for medical purposes, by the intravenous injection of muscle relaxing drugs. The system contains three sections: an electric stimulator for motor nerves; a section that receives the signals coming from a force transducer attached to the corresponding muscle, evaluates the relative strength of the ensuing muscular contractions and stores the results in four registers, and a section that drives a liquid crystal display.