{"title":"Experimental Assessment of Progressive Collapse of Reinforced Concrete Beam-Column Assemblages","authors":"A. Mahmoud, F. Beshara, O. El-Mahdy, Ahmed Khater","doi":"10.21608/ijaebs.2023.164907.1044","DOIUrl":null,"url":null,"abstract":"This paper introduces the experimental program implemented to study the load-carrying capacity of seven reinforced concrete beam-column assemblages under monotonic vertical load against progressive collapse due to removal of the interior column. The specimens were designed and detailed according to the Egyptian code provisions. The specimens were one-quarter of the full scale and designed with and without seismic detailing to verify the effect of reinforcement detailing and flanges on the assemblage structural behavior. Each specimen represented a two-consecutive beam spans subsequent to the elimination of the first story interior column. In all assemblages, the external two columns were restrained against the vertical and the horizontal deformations and loads were applied monotonically at the top of the interior column stub. For each load step, the results of","PeriodicalId":360790,"journal":{"name":"International Journal of Advanced Engineering and Business Sciences","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Engineering and Business Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/ijaebs.2023.164907.1044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper introduces the experimental program implemented to study the load-carrying capacity of seven reinforced concrete beam-column assemblages under monotonic vertical load against progressive collapse due to removal of the interior column. The specimens were designed and detailed according to the Egyptian code provisions. The specimens were one-quarter of the full scale and designed with and without seismic detailing to verify the effect of reinforcement detailing and flanges on the assemblage structural behavior. Each specimen represented a two-consecutive beam spans subsequent to the elimination of the first story interior column. In all assemblages, the external two columns were restrained against the vertical and the horizontal deformations and loads were applied monotonically at the top of the interior column stub. For each load step, the results of