Influence of rotor capacitance in on-line rotor ground fault location method for synchronous machines with static excitation

F. Blanquez, M. Aranda, E. Rebollo, C. Platero
{"title":"Influence of rotor capacitance in on-line rotor ground fault location method for synchronous machines with static excitation","authors":"F. Blanquez, M. Aranda, E. Rebollo, C. Platero","doi":"10.1109/EEEIC-2.2013.6737916","DOIUrl":null,"url":null,"abstract":"This paper presents results about the influence of rotor capacitance in the on-line rotor ground fault location method for synchronous machines with static excitation. The location method is based on the measurement of the voltage in a grounding resistance, connected to the neutral of the excitation transformer. Due to the effect of the rotor capacitance to ground on large synchronous generators, it is observed that waveform of the neutral voltage is perturbed, and it causes an error in the fault location in case of defect in the DC side. Firstly, the influence of the fault resistance value and the fault position is evaluated through computer simulations. Then, the impact of the rotor capacitance in the accuracy of the detection and location method is analyzed in case of ground fault, as well as in healthy operating condition.","PeriodicalId":445295,"journal":{"name":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC-2.2013.6737916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents results about the influence of rotor capacitance in the on-line rotor ground fault location method for synchronous machines with static excitation. The location method is based on the measurement of the voltage in a grounding resistance, connected to the neutral of the excitation transformer. Due to the effect of the rotor capacitance to ground on large synchronous generators, it is observed that waveform of the neutral voltage is perturbed, and it causes an error in the fault location in case of defect in the DC side. Firstly, the influence of the fault resistance value and the fault position is evaluated through computer simulations. Then, the impact of the rotor capacitance in the accuracy of the detection and location method is analyzed in case of ground fault, as well as in healthy operating condition.
静态励磁同步电机转子接地故障在线定位方法中转子电容的影响
本文研究了静态励磁同步电机转子接地故障在线定位方法中转子电容的影响。定位方法是基于测量接地电阻中的电压,该接地电阻连接到励磁变压器的中性点。大型同步发电机由于转子对地电容的影响,观察到中性点电压波形受到扰动,当直流侧出现缺陷时,会造成故障定位误差。首先,通过计算机仿真评估了故障电阻值和故障位置的影响;然后,分析了在接地故障和正常运行情况下,转子电容对检测定位方法精度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信