Comparison of Current-Only Directional Protection in AC and DC Power Systems

K. Satpathi, A. Ukil, S. Nag, J. Pou, Michael Adam Zadrodnik
{"title":"Comparison of Current-Only Directional Protection in AC and DC Power Systems","authors":"K. Satpathi, A. Ukil, S. Nag, J. Pou, Michael Adam Zadrodnik","doi":"10.1109/ISGT-ASIA.2018.8467831","DOIUrl":null,"url":null,"abstract":"Future distribution systems are conceived to be largely based on hybrid ac/dc power system architectures thus reapingthe benefits of both ac and dc power systems. Directional protection is expected to play an important role for selectivefault identification in such distribution systems. Traditionally, the directional protection comprises of a directional element working in conjunction with the overcurrent based fault detection algorithm. The selective operation is ensured by the definite mean-time operation of the overcurrent relays. For ac systems this directional element is based on the voltage polarisation techniques. In recent years, current-only directional element has been proposed which takes either pre-fault or the post-fault current as the polarising quantity. For the dc systems, directional protection is based on the operation only with the directional element which might maloperate during high-impedance faults. A new directional protection of dc power system is proposed in this paper which uses the time-domain based pre-fault current magnitude as thepolarising quantity while frequency-domain of the fault current for fault detection. The proposed current-only directional protection of dc system is compared with that of ac systems. AC and dc power systems of similar topologies and power levels are considered and the faults of various impedances are tested to compare the current-only ac and dc directional protection. It is observed that the current-only ac directional protection has limitations at high-impedance faults while the proposed current-only dc directional protection can easily detect high-impedance faults.","PeriodicalId":126140,"journal":{"name":"2018 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2018.8467831","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Future distribution systems are conceived to be largely based on hybrid ac/dc power system architectures thus reapingthe benefits of both ac and dc power systems. Directional protection is expected to play an important role for selectivefault identification in such distribution systems. Traditionally, the directional protection comprises of a directional element working in conjunction with the overcurrent based fault detection algorithm. The selective operation is ensured by the definite mean-time operation of the overcurrent relays. For ac systems this directional element is based on the voltage polarisation techniques. In recent years, current-only directional element has been proposed which takes either pre-fault or the post-fault current as the polarising quantity. For the dc systems, directional protection is based on the operation only with the directional element which might maloperate during high-impedance faults. A new directional protection of dc power system is proposed in this paper which uses the time-domain based pre-fault current magnitude as thepolarising quantity while frequency-domain of the fault current for fault detection. The proposed current-only directional protection of dc system is compared with that of ac systems. AC and dc power systems of similar topologies and power levels are considered and the faults of various impedances are tested to compare the current-only ac and dc directional protection. It is observed that the current-only ac directional protection has limitations at high-impedance faults while the proposed current-only dc directional protection can easily detect high-impedance faults.
交流与直流电力系统中纯电流定向保护的比较
未来的配电系统被认为主要基于混合交流/直流电力系统架构,从而获得交流和直流电力系统的好处。在这类配电系统中,定向保护将在选择性故障识别中发挥重要作用。传统上,定向保护包括一个定向元件与基于过流的故障检测算法一起工作。通过确定过流继电器的同步动作,保证了选择性动作。对于交流系统,定向元件基于电压极化技术。近年来提出了以故障前电流或故障后电流作为极化量的纯电流定向元件。对于直流系统来说,方向保护是基于在高阻抗故障时可能发生误动作的方向元件的运行。本文提出了一种新的直流电力系统定向保护方法,利用基于时域的故障前电流幅值作为极化量,利用故障电流的频域进行故障检测。将所提出的直流系统的电流定向保护与交流系统的电流定向保护进行了比较。考虑具有相似拓扑结构和功率水平的交流和直流电源系统,并对不同阻抗的故障进行了测试,以比较纯电流交流和直流方向保护。结果表明,纯电流交流方向保护在检测高阻抗故障时存在一定的局限性,而纯电流直流方向保护可以方便地检测高阻抗故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书