{"title":"An Improved (F&V) Based Passive Islanding Detection Strategy With Reliability Evaluation","authors":"Sowmya Ramachandradurai, K. Naravanan","doi":"10.1109/ISGTLatinAmerica52371.2021.9543002","DOIUrl":null,"url":null,"abstract":"The quantitative reliability analysis plays a significant role in assessing the performance of the distribution system operation strategy. This analysis is greatly influenced by customer interruption. In this paper, the islanding issue is considered as a customer interruption. The islanding is detected by simultaneous measurement of F&V (Frequency and Voltage) variation using passive islanding detection method. The detected islanding is prevented by installing diesel generator or battery depending on the power balance in the detected islanded buses. In this study, the proposed methods of islanding detection and prevention is tested on IEEE- 135 radial bus distribution system in the presence of various Distribution Generation (DG) units.","PeriodicalId":120262,"journal":{"name":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The quantitative reliability analysis plays a significant role in assessing the performance of the distribution system operation strategy. This analysis is greatly influenced by customer interruption. In this paper, the islanding issue is considered as a customer interruption. The islanding is detected by simultaneous measurement of F&V (Frequency and Voltage) variation using passive islanding detection method. The detected islanding is prevented by installing diesel generator or battery depending on the power balance in the detected islanded buses. In this study, the proposed methods of islanding detection and prevention is tested on IEEE- 135 radial bus distribution system in the presence of various Distribution Generation (DG) units.
一种改进的基于F&V的无源孤岛检测策略及可靠性评估
定量可靠性分析对配电系统运行策略的绩效评估具有重要意义。这种分析受到客户中断的很大影响。本文将孤岛问题视为客户中断问题。采用无源孤岛检测方法,通过同时测量频率和电压的变化来检测孤岛。根据检测到的孤岛总线的功率平衡,通过安装柴油发电机或电池来防止检测到的孤岛。在本研究中,在IEEE- 135径向母线配电系统中,在多个配电发电机组存在的情况下,对所提出的孤岛检测和预防方法进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信