{"title":"Research on the optimization of UHV AC composite insulators' shed","authors":"Chuyan Zhang, Li-ming Wang, Zhi-dong Jia, Z. Guan","doi":"10.1109/ICHVE.2010.5640757","DOIUrl":null,"url":null,"abstract":"Composite insulators' shed plays a very important role in their contamination performance. As we have known, composite insulators with different shed profiles have different contamination flashover performances. In this paper, studies mainly focusing on the optimal design of composite insulators' shed. Based on the results of a great deal of artificial contamination test for specimen composite insulators with different profiles, this paper carried out the relationship between the shed parameter and the contamination flashover voltage. By the above work, flashover voltages of composite insulators can be enhanced greatly and the composite insulators will have higher utilization rate of the leakage distance. Therefore, the dimension of towers will be decreased and the cost of transmission systems will be reduced, especially in heavy pollution areas. Accordingly, this work can provide theoretical support of the external insulation design and the selection of insulators for 1000 kV UHV AC transmission projects in China.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Composite insulators' shed plays a very important role in their contamination performance. As we have known, composite insulators with different shed profiles have different contamination flashover performances. In this paper, studies mainly focusing on the optimal design of composite insulators' shed. Based on the results of a great deal of artificial contamination test for specimen composite insulators with different profiles, this paper carried out the relationship between the shed parameter and the contamination flashover voltage. By the above work, flashover voltages of composite insulators can be enhanced greatly and the composite insulators will have higher utilization rate of the leakage distance. Therefore, the dimension of towers will be decreased and the cost of transmission systems will be reduced, especially in heavy pollution areas. Accordingly, this work can provide theoretical support of the external insulation design and the selection of insulators for 1000 kV UHV AC transmission projects in China.
特高压交流复合绝缘子棚架优化研究
复合绝缘子的棚子对绝缘子的污染性能起着重要的作用。众所周知,不同棚型的复合绝缘子具有不同的污闪性能。本文主要对复合绝缘子棚的优化设计进行了研究。在对不同外形的复合绝缘子试样进行大量人工污污试验的基础上,研究了绝缘子棚子参数与污污闪络电压的关系。通过以上工作,可以大大提高复合绝缘子的闪络电压,提高复合绝缘子的漏电距离利用率。因此,塔的尺寸将会减小,输电系统的成本将会降低,特别是在重污染地区。从而为国内1000kv特高压交流输电工程的外绝缘设计和绝缘子的选用提供理论支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信