An Ionization Chamber Using A Magnetically Suspended Electrode And Its Application To Environmental Radiation Monitoring

E. Tanaka, K. Koike, Y. Mori
{"title":"An Ionization Chamber Using A Magnetically Suspended Electrode And Its Application To Environmental Radiation Monitoring","authors":"E. Tanaka, K. Koike, Y. Mori","doi":"10.1109/NSSMIC.1990.693380","DOIUrl":null,"url":null,"abstract":"A high-sensitivity ionization chamber has been developed for environmental radiation monitoring. The ion-collecting electrode is suspended by magnetic force without using all insulator so that the chamber is free from background current (such as leakage current and piezoelectricity) caused by the insulator. The electrode is reset periodically (every hour), and the ionization current is measured by detecting the amount of charge which flows through the reset contact. Experiments show that the chamber is useful for monitoring environmental gamma-ray dose (when the chamber is closed) or radon concentration in air (when the chamber is opened). The minimum detectable magnitude of ionization current is about 10/sup -17./ A, when the electrode is reset every hour. >","PeriodicalId":234642,"journal":{"name":"1990 IEEE Nuclear Science Symposium Conference Record","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1990 IEEE Nuclear Science Symposium Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1990.693380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

A high-sensitivity ionization chamber has been developed for environmental radiation monitoring. The ion-collecting electrode is suspended by magnetic force without using all insulator so that the chamber is free from background current (such as leakage current and piezoelectricity) caused by the insulator. The electrode is reset periodically (every hour), and the ionization current is measured by detecting the amount of charge which flows through the reset contact. Experiments show that the chamber is useful for monitoring environmental gamma-ray dose (when the chamber is closed) or radon concentration in air (when the chamber is opened). The minimum detectable magnitude of ionization current is about 10/sup -17./ A, when the electrode is reset every hour. >
磁悬浮电极电离室及其在环境辐射监测中的应用
研制了一种用于环境辐射监测的高灵敏度电离室。离子收集电极在不使用所有绝缘体的情况下通过磁力悬浮,使腔室不受绝缘体引起的背景电流(如漏电流和压电)的影响。电极周期性(每小时)复位,通过检测流过复位触点的电荷量来测量电离电流。实验表明,该腔室可用于监测环境伽马射线剂量(当腔室关闭时)或空气中的氡浓度(当腔室打开时)。可探测到的电离电流的最小量级约为10/sup -17。/ A,电极每小时复位一次。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书