The Structural Performance Analysis of Base-Isolated Hospital Buildings with Analysis Modal (Case Study: General Hospital in Labuhan Batu Utara Regency Area)

M. Irwansyah, J. Tarigan, Zulfazly Putra
{"title":"The Structural Performance Analysis of Base-Isolated Hospital Buildings with Analysis Modal (Case Study: General Hospital in Labuhan Batu Utara Regency Area)","authors":"M. Irwansyah, J. Tarigan, Zulfazly Putra","doi":"10.32734/jet.v1i2.736","DOIUrl":null,"url":null,"abstract":"The development of earthquake analysis towards structures is required to prevent damages and loss in buildings due to earthquakes. The base isolation system is a simple design approach for earthquake-resistant buildings to protect the structures and components from the risk of earthquake damages by using the concept of reducing earthquake forces. This research aims to analyze the performance of a general hospital building in Labura Regency area in order to know the safety of the building in terms of period, frequency, base shear force, displacement and earthquake force, used the base isolators and without the base isolators. The method used is response-spectrum dynamic analysis by ETABS v2016 program. From the calculation of structural analysis, the application of base isolation is able to build up the period of the structure, therefore, the maximum acceleration of earthquakes can be reduced at certain period. There is an average increase by 48.21% of the structural period compared to non-isolated base structure, and the frequency that occurs in structures using base isolators is smaller than without base isolators. The friction force obtained is smaller compared to the structures without dampers. Base-isolated building structures observed have bigger displacement than non-base isolated structures. The average rise of the building displacement is 27.14% at x and 2.74% at y directions. In base-isolated structures, earthquake forces are reduced averagely by 57.51% at x and 82.73% at y directions. The analysis of structural performance, General Hospital in Labura Regency is categorized to Immediate Occupancy (IO) in which the building structures are safe with no significant risk of fatalities due to structural failures, there are no any significant damages and the building can be used and functioned/operated again immediately.","PeriodicalId":117730,"journal":{"name":"Simetrikal: Journal of Engineering and Technology","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Simetrikal: Journal of Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32734/jet.v1i2.736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The development of earthquake analysis towards structures is required to prevent damages and loss in buildings due to earthquakes. The base isolation system is a simple design approach for earthquake-resistant buildings to protect the structures and components from the risk of earthquake damages by using the concept of reducing earthquake forces. This research aims to analyze the performance of a general hospital building in Labura Regency area in order to know the safety of the building in terms of period, frequency, base shear force, displacement and earthquake force, used the base isolators and without the base isolators. The method used is response-spectrum dynamic analysis by ETABS v2016 program. From the calculation of structural analysis, the application of base isolation is able to build up the period of the structure, therefore, the maximum acceleration of earthquakes can be reduced at certain period. There is an average increase by 48.21% of the structural period compared to non-isolated base structure, and the frequency that occurs in structures using base isolators is smaller than without base isolators. The friction force obtained is smaller compared to the structures without dampers. Base-isolated building structures observed have bigger displacement than non-base isolated structures. The average rise of the building displacement is 27.14% at x and 2.74% at y directions. In base-isolated structures, earthquake forces are reduced averagely by 57.51% at x and 82.73% at y directions. The analysis of structural performance, General Hospital in Labura Regency is categorized to Immediate Occupancy (IO) in which the building structures are safe with no significant risk of fatalities due to structural failures, there are no any significant damages and the building can be used and functioned/operated again immediately.
基于分析模态的基础隔离式医院建筑结构性能分析(以纳布汉Batu Utara地区综合医院为例)
为了防止地震对建筑物造成的破坏和损失,需要对结构进行地震分析。基础隔震系统是一种简单的抗震建筑设计方法,通过减少地震力的概念来保护结构和部件免受地震破坏的风险。本研究旨在通过对Labura Regency地区某综合医院建筑的周期、频率、基础剪力、位移和地震力的性能分析,了解该建筑在使用基础隔震器和不使用基础隔震器情况下的安全性。采用ETABS v2016程序进行响应谱动态分析。从结构分析计算来看,基础隔震的应用可以建立结构的周期,从而在一定的周期内减小地震的最大加速度。与未隔离的基基结构相比,结构周期平均增加48.21%,并且在使用基基隔离器的结构中发生的频率小于未使用基基隔离器的结构。与没有阻尼器的结构相比,得到的摩擦力较小。基础隔震结构比非基础隔震结构具有更大的位移。建筑位移在x方向上平均上升27.14%,在y方向上平均上升2.74%。在基础隔震结构中,x方向的地震力平均降低57.51%,y方向的地震力平均降低82.73%。结构性能分析,Labura Regency的综合医院被归类为立即使用(IO),其中建筑结构是安全的,没有因结构故障造成的重大死亡风险,没有任何重大损害,建筑物可以立即使用和运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信