Control positioning of torsional electrostatic actuators by current driving

R. N. Guardia, R. Aigner, W. Nessler, M. Handtmann, L. Castañer
{"title":"Control positioning of torsional electrostatic actuators by current driving","authors":"R. N. Guardia, R. Aigner, W. Nessler, M. Handtmann, L. Castañer","doi":"10.1109/ASDAM.2000.889457","DOIUrl":null,"url":null,"abstract":"In this paper, a novel charge control procedure of the moveable electrode of a torsional electrostatic actuator is presented It is demonstrated that pull-in charge limits the controllable range not only with parasitic capacitances but also without them. Charge is injected into the actuator by means of a switched current source. Current injection is controlled measuring voltage drop on a series capacitance, and a$@flop closing the loop provides the synchronous operation of the system. In fact, the control circuit is a current sigma-delta control.","PeriodicalId":303962,"journal":{"name":"ASDAM 2000. Conference Proceedings. Third International EuroConference on Advanced Semiconductor Devices and Microsystems (Cat. No.00EX386)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASDAM 2000. Conference Proceedings. Third International EuroConference on Advanced Semiconductor Devices and Microsystems (Cat. No.00EX386)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASDAM.2000.889457","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

In this paper, a novel charge control procedure of the moveable electrode of a torsional electrostatic actuator is presented It is demonstrated that pull-in charge limits the controllable range not only with parasitic capacitances but also without them. Charge is injected into the actuator by means of a switched current source. Current injection is controlled measuring voltage drop on a series capacitance, and a$@flop closing the loop provides the synchronous operation of the system. In fact, the control circuit is a current sigma-delta control.
通过电流驱动控制扭转静电致动器的定位
本文提出了一种新的扭转静电致动器可动电极的电荷控制方法,证明了在有寄生电容和无寄生电容的情况下,拉入电荷限制了可控范围。电荷通过开关电流源注入致动器。电流注入是通过测量串联电容上的压降来控制的,而闭合回路的$@触发器提供了系统的同步操作。实际上,控制电路是电流σ - δ控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信