Sensorex: The Challenges for Engineering Implementation of Low-Cost Non-Invasive Pulse Oximeter Applicable to Diverse Patient Population

D. Lipchak, A. Chupov
{"title":"Sensorex: The Challenges for Engineering Implementation of Low-Cost Non-Invasive Pulse Oximeter Applicable to Diverse Patient Population","authors":"D. Lipchak, A. Chupov","doi":"10.1109/EDM52169.2021.9507630","DOIUrl":null,"url":null,"abstract":"Two wavelengths transmittance non-invasive pulse oximetry is commonly used in clinical practice. However, in a need of quick blood oxygen diagnostic assessment, a low-cost pulse oximeter needs to operate at a wide variety of patients using the same fingertip sensor or, at least, using a sensor of identical model and manufacturer. The average intensity for both optical and near-infrared light transmitted through the fingertip can be higher or lower depending on the volume of the finger, skin colour, tissue composition, and thus varies for people of different ages, gender, morphology, or national origin. Therefore, the device must correctly calculate the pulse oximetry parameters for signals with different tissue transmittances. Also, for the different age groups, different types of fingertip sensors are usually used (e.q. adhesive, clips, silicone mittens, etc.), the difference in fastening of the sensor can potentially distort the measurement results. A SENSOREX hardware and software provides correct extraction of saturation and perfusion coefficient and also extracts a plethysmographic wave suitable for subsequent adaptive signal processing implemented in the device to eliminate the effects of natural patient movement. At the time of the publication, the SENSOREX is at the final stage of Russian Federation state registration as a medical device for professional and home care usage. The implemented software-hardware solution is suitable for different categories of patients and uses with Nellcor - compatible fingertip sensors of various way of attachments. During the development, contradictions in the stakeholders' requirements and regulatory documents were considered, which entailed difficulties in engineering implementation. The paper presents the found methods to overcome those challenges and discusses the further promising development of the software and hardware complex and subsequent signal processing.","PeriodicalId":281783,"journal":{"name":"2021 IEEE 22nd International Conference of Young Professionals in Electron Devices and Materials (EDM)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 22nd International Conference of Young Professionals in Electron Devices and Materials (EDM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDM52169.2021.9507630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Two wavelengths transmittance non-invasive pulse oximetry is commonly used in clinical practice. However, in a need of quick blood oxygen diagnostic assessment, a low-cost pulse oximeter needs to operate at a wide variety of patients using the same fingertip sensor or, at least, using a sensor of identical model and manufacturer. The average intensity for both optical and near-infrared light transmitted through the fingertip can be higher or lower depending on the volume of the finger, skin colour, tissue composition, and thus varies for people of different ages, gender, morphology, or national origin. Therefore, the device must correctly calculate the pulse oximetry parameters for signals with different tissue transmittances. Also, for the different age groups, different types of fingertip sensors are usually used (e.q. adhesive, clips, silicone mittens, etc.), the difference in fastening of the sensor can potentially distort the measurement results. A SENSOREX hardware and software provides correct extraction of saturation and perfusion coefficient and also extracts a plethysmographic wave suitable for subsequent adaptive signal processing implemented in the device to eliminate the effects of natural patient movement. At the time of the publication, the SENSOREX is at the final stage of Russian Federation state registration as a medical device for professional and home care usage. The implemented software-hardware solution is suitable for different categories of patients and uses with Nellcor - compatible fingertip sensors of various way of attachments. During the development, contradictions in the stakeholders' requirements and regulatory documents were considered, which entailed difficulties in engineering implementation. The paper presents the found methods to overcome those challenges and discusses the further promising development of the software and hardware complex and subsequent signal processing.
Sensorex:适用于不同患者群体的低成本无创脉搏血氧仪工程实施的挑战
双波长透过率无创脉搏血氧仪是临床上常用的一种方法。然而,在需要快速血氧诊断评估时,低成本脉搏血氧仪需要使用相同的指尖传感器或至少使用相同型号和制造商的传感器对各种患者进行操作。通过指尖传输的可见光和近红外光的平均强度可高或低,这取决于手指的体积、肤色、组织组成,因此因年龄、性别、形态或国籍不同而异。因此,设备必须正确计算不同组织透射率信号的脉搏血氧测定参数。此外,对于不同的年龄组,通常使用不同类型的指尖传感器(例如粘合剂,夹子,硅胶连指手套等),传感器紧固的差异可能会扭曲测量结果。SENSOREX硬件和软件提供饱和度和灌注系数的正确提取,并提取适合随后在设备中实施的自适应信号处理的脉搏波,以消除患者自然运动的影响。在发布时,SENSOREX作为专业和家庭护理使用的医疗设备处于俄罗斯联邦国家注册的最后阶段。实现的软硬件解决方案适用于不同类别的患者,并与Nellcor兼容的各种附件方式的指尖传感器一起使用。在开发过程中,考虑到利益相关者的要求和规范性文件的矛盾,给工程实施带来了困难。本文介绍了克服这些挑战的现有方法,并讨论了软硬件复杂和后续信号处理的进一步发展前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书