{"title":"Numerical Simulation of Q-Switched Supersonic Flow Chemical Oxygen-Iodine Laser by Solving Time-Dependent Paraxial Wave Equation","authors":"Masataro Suzuki, H. Matsueda, W. Masuda","doi":"10.1299/JSMEB.49.1212","DOIUrl":null,"url":null,"abstract":"The quality and power of an extracted beam from a Q-switched supersonic flow chemical oxygen-iodine laser have been investigated by numerical simulation. The flow system adopted in this study is the throat-mixing system proposed in a previous paper. Three-dimensional calculation for optics is coupled with one-dimensional calculation for gas flow including chemical reactions. Both geometric and wave optics are calculated and compared to assess the effects of diffraction. Wave optics is calculated with a time-dependent paraxial wave equation. The results indicate that wave and geometric optics are qualitatively similar in the time-dependent behavior of beam power. Quantitatively, it is found that diffraction reduces the extracted power by 9%. It is also found from the spreading half-angle of the beam for wave optics that the beam quality at a maximum power is equivalent to that of a plane wave; however, it is lower than that of continuous extraction.","PeriodicalId":414195,"journal":{"name":"Jsme International Journal Series B-fluids and Thermal Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jsme International Journal Series B-fluids and Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/JSMEB.49.1212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The quality and power of an extracted beam from a Q-switched supersonic flow chemical oxygen-iodine laser have been investigated by numerical simulation. The flow system adopted in this study is the throat-mixing system proposed in a previous paper. Three-dimensional calculation for optics is coupled with one-dimensional calculation for gas flow including chemical reactions. Both geometric and wave optics are calculated and compared to assess the effects of diffraction. Wave optics is calculated with a time-dependent paraxial wave equation. The results indicate that wave and geometric optics are qualitatively similar in the time-dependent behavior of beam power. Quantitatively, it is found that diffraction reduces the extracted power by 9%. It is also found from the spreading half-angle of the beam for wave optics that the beam quality at a maximum power is equivalent to that of a plane wave; however, it is lower than that of continuous extraction.