{"title":"Experimental validation of nonlinear PID model for human standing with large body sway","authors":"Sekiya Noro, T. Funato, S. Aoi, K. Nakano, K. Tsuchiya","doi":"10.1109/ECTICON.2014.6839874","DOIUrl":null,"url":null,"abstract":"Human generates very slow (<;1[Hz]) and large (>20[mm]) body sway. This sway is considered to reflect the characteristic of human neural control. We propose a human control model with nonlinearlity and the effect of nonlinearlity is considered by mathematical analysis and simulation. As a result, we found that the proposed model has bifurcation structure with the magnitude of control gain. We consider that body sway is caused by this bifurcation structure. In order to verify the existence of such a nonlinear nature in human, we performed human experiment with two floor environments: fix and rotate floors. As a result, we verified the existence of nonlinearlity in human body sway and showed the potential existence of bifurcation structure.","PeriodicalId":347166,"journal":{"name":"2014 11th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 11th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2014.6839874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Human generates very slow (<;1[Hz]) and large (>20[mm]) body sway. This sway is considered to reflect the characteristic of human neural control. We propose a human control model with nonlinearlity and the effect of nonlinearlity is considered by mathematical analysis and simulation. As a result, we found that the proposed model has bifurcation structure with the magnitude of control gain. We consider that body sway is caused by this bifurcation structure. In order to verify the existence of such a nonlinear nature in human, we performed human experiment with two floor environments: fix and rotate floors. As a result, we verified the existence of nonlinearlity in human body sway and showed the potential existence of bifurcation structure.
人体大摆站立非线性PID模型的实验验证
人体产生非常缓慢(20[毫米])的身体摇摆。这种摇摆被认为反映了人类神经控制的特征。提出了一种具有非线性的人控模型,并通过数学分析和仿真考虑了非线性的影响。结果表明,该模型具有随控制增益大小而变化的分岔结构。我们认为身体的摇摆是由这种分岔结构引起的。为了验证这种非线性在人体中的存在,我们在固定楼层和旋转楼层两种楼层环境下进行了人体实验。验证了人体摆动非线性的存在性,表明了分岔结构的潜在存在性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信