[Comparative study of the intraoperative effectiveness of 5% human albumin or 10% hydroxyethyl starch (HAES-steril) on hemodynamics and oxygen transport in 40 patients].

K Hankeln, R Senker, M Beez
{"title":"[Comparative study of the intraoperative effectiveness of 5% human albumin or 10% hydroxyethyl starch (HAES-steril) on hemodynamics and oxygen transport in 40 patients].","authors":"K Hankeln,&nbsp;R Senker,&nbsp;M Beez","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In 40 patients, whose expected hemodynamic instability during surgery necessitated invasive monitoring (Swan-Ganz catheter) and arterial pressure monitoring the hemodynamic and oxygen transport parameters in conditions of hypervolemic hemodilution were investigated in randomized tests. After insertion of an arterial catheter (arteria radialis) as well as Swan-Ganz pulmonary arterial catheter via the vena jugularis interna, one of the two volume substitutes selected at random was infused in quantities of 125 ml/5 min and the hemodynamic changes were measured after infusion of 500 ml and finally after a wedge pressure of 18 mmHg was reached. Using either solution, the measurements indicated significant increases in mean arterial pressure as well as in central venous pressure (ZVD) and wedge pressure. The cardiac index, left ventricular stroke work index, and stroke output rose consecutively and pulmonary vascular resistance went down in both test groups. In the case of both volume substitutes, there was an improvement in oxygen availability. The hemoglobin content decreased in both groups, though to different degrees in each group. Although the hydroxyethyl starch group registered a greater improvement in the cardiac index, a bigger decrease in pulmonary vascular resistance, a higher rise in the left ventricular stroke work index and a more significant improvement in stroke output, smaller quantities of the volume substitute were required in this group than in the group in which volume substitution was carried out with human albumin 5%.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":77545,"journal":{"name":"Infusionstherapie (Basel, Switzerland)","volume":"17 3","pages":"135-40"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infusionstherapie (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In 40 patients, whose expected hemodynamic instability during surgery necessitated invasive monitoring (Swan-Ganz catheter) and arterial pressure monitoring the hemodynamic and oxygen transport parameters in conditions of hypervolemic hemodilution were investigated in randomized tests. After insertion of an arterial catheter (arteria radialis) as well as Swan-Ganz pulmonary arterial catheter via the vena jugularis interna, one of the two volume substitutes selected at random was infused in quantities of 125 ml/5 min and the hemodynamic changes were measured after infusion of 500 ml and finally after a wedge pressure of 18 mmHg was reached. Using either solution, the measurements indicated significant increases in mean arterial pressure as well as in central venous pressure (ZVD) and wedge pressure. The cardiac index, left ventricular stroke work index, and stroke output rose consecutively and pulmonary vascular resistance went down in both test groups. In the case of both volume substitutes, there was an improvement in oxygen availability. The hemoglobin content decreased in both groups, though to different degrees in each group. Although the hydroxyethyl starch group registered a greater improvement in the cardiac index, a bigger decrease in pulmonary vascular resistance, a higher rise in the left ventricular stroke work index and a more significant improvement in stroke output, smaller quantities of the volume substitute were required in this group than in the group in which volume substitution was carried out with human albumin 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

[术中5%人白蛋白与10%羟乙基淀粉(HAES-steril)对40例患者血流动力学和氧转运效果的比较研究]。
对40例手术中血流动力学不稳定需要有创监测(Swan-Ganz导管)和动脉压监测的患者进行随机试验,研究高容性血液稀释条件下的血流动力学和氧转运参数。经颈内静脉置入动脉导管(桡动脉)和Swan-Ganz肺动脉导管后,随机选择两种体积代用物中的一种,以125ml / 5min的剂量输注,分别在输注500ml和18mmhg楔压后测量血流动力学变化。使用任何一种溶液,测量结果都表明平均动脉压、中心静脉压(ZVD)和楔压显著增加。两组心脏指数、左室卒中工作指数、卒中输出量均连续升高,肺血管阻力下降。在两种体积替代品的情况下,氧气的可用性都有所改善。两组血红蛋白含量均有所下降,但程度不同。虽然羟乙基淀粉组心脏指数改善更大,肺血管阻力下降更大,左室卒中功指数上升更高,卒中输出量改善更显著,但与用5%人白蛋白进行容量替代的组相比,该组所需的容量替代量更少。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信