A New Approach of the Percutaneous Arterial Oxygen Saturation (SpO2) Measurement

Koji Nakai, Harumi Watanabe, Sachiko Takahashi, Hiromi Miyamoto, A. Doi, A. Hanakuma, Yusuke Morishita, Tomohiro Sawada, Masaya Otsuji, Y. Hirate, Yoshiaki Shindo, Koji Kosuge
{"title":"A New Approach of the Percutaneous Arterial Oxygen Saturation (SpO2) Measurement","authors":"Koji Nakai, Harumi Watanabe, Sachiko Takahashi, Hiromi Miyamoto, A. Doi, A. Hanakuma, Yusuke Morishita, Tomohiro Sawada, Masaya Otsuji, Y. Hirate, Yoshiaki Shindo, Koji Kosuge","doi":"10.4286/JJMI.79.638","DOIUrl":null,"url":null,"abstract":"We studied the utility and drawbacks of the earlobe probe sensor on the percutaneous arterial oxygen saturation (SpO2) measurement. The SpO2 from the earlobe, forehead and finger sensor were measured simultaneously, and then changes of SpO2 readings induced by medical interferences and influence by the sensor attachment were compared among three types of sensor. The SpO2 from the earlobe sensor responded to the rapid change of patient clinical condition as well as from the forehead and finger sensor. The pulse wave signal from the earlobe sensor was more stable compared to those from forehead and finger sensor, but the time to display SpO2 readings after the earlobe sensor attachment was similar to the forehead sensor and it took longer than that in case of the finger sensor attachment. Some cases were difficult to measure SpO2 because of extremely thin earlobe and edema of earlobe. The long-term attachment of the earlobe sensor did not leave any surface imprint on the patient skin that is often found with the use of forehead and finger sensor. Also no patient had removed the earlobe sensor on a voluntary basis. While the SpO2 measurement with the earlobe sensor may be affected by several factors such as the earlobe shape and the peripheral circulation, it is the least painful for the patient. The active utilization of the earlobe sensor in clinical practice is promising as a new approach of the SpO2 measurement.","PeriodicalId":223355,"journal":{"name":"The Japanese journal of medical instrumentation","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Japanese journal of medical instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4286/JJMI.79.638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We studied the utility and drawbacks of the earlobe probe sensor on the percutaneous arterial oxygen saturation (SpO2) measurement. The SpO2 from the earlobe, forehead and finger sensor were measured simultaneously, and then changes of SpO2 readings induced by medical interferences and influence by the sensor attachment were compared among three types of sensor. The SpO2 from the earlobe sensor responded to the rapid change of patient clinical condition as well as from the forehead and finger sensor. The pulse wave signal from the earlobe sensor was more stable compared to those from forehead and finger sensor, but the time to display SpO2 readings after the earlobe sensor attachment was similar to the forehead sensor and it took longer than that in case of the finger sensor attachment. Some cases were difficult to measure SpO2 because of extremely thin earlobe and edema of earlobe. The long-term attachment of the earlobe sensor did not leave any surface imprint on the patient skin that is often found with the use of forehead and finger sensor. Also no patient had removed the earlobe sensor on a voluntary basis. While the SpO2 measurement with the earlobe sensor may be affected by several factors such as the earlobe shape and the peripheral circulation, it is the least painful for the patient. The active utilization of the earlobe sensor in clinical practice is promising as a new approach of the SpO2 measurement.
一种经皮动脉血氧饱和度(SpO2)测定的新方法
我们研究了耳垂探头传感器在经皮动脉血氧饱和度(SpO2)测量中的应用和不足。同时测量耳垂、前额和手指传感器的SpO2,比较三种传感器在医疗干扰和传感器附着影响下SpO2读数的变化。耳垂传感器的SpO2对患者临床状况的快速变化有响应,前额和手指传感器的SpO2也有响应。耳垂传感器的脉冲波信号比额头和手指传感器的脉冲波信号更稳定,但耳垂传感器附着后的SpO2读数显示时间与额头传感器相似,且比手指传感器附着时的时间更长。部分病例因耳垂极薄及耳垂水肿难以测量SpO2。耳垂传感器的长期附着不会在患者皮肤上留下前额和手指传感器经常发现的任何表面印记。此外,没有患者自愿移除耳垂传感器。虽然耳垂传感器测量SpO2可能会受到耳垂形状和外周循环等多种因素的影响,但它对患者来说是最不痛苦的。耳垂传感器作为一种新的SpO2测量方法,在临床中得到了积极的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书