{"title":"Reduced THD Model of Single Stage Three-Phase Boost Inverter","authors":"Manish Kumar Barwar, P. Tripathi, P. Thakura","doi":"10.1109/ICEES.2018.8442409","DOIUrl":null,"url":null,"abstract":"This paper presents a mathematical calculation of a Boost Inverter for reduced THD. The mathematical model has been verified by the MATLAB Simulink model. Proposed model has been simulated for a switching frequency of 50Hz. The THD in the output waveform has been calculated using MATLAB FFT in accordance with IEEE STD 519–2014 and shows a minimal harmonic distortion.","PeriodicalId":134828,"journal":{"name":"2018 4th International Conference on Electrical Energy Systems (ICEES)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Electrical Energy Systems (ICEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2018.8442409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This paper presents a mathematical calculation of a Boost Inverter for reduced THD. The mathematical model has been verified by the MATLAB Simulink model. Proposed model has been simulated for a switching frequency of 50Hz. The THD in the output waveform has been calculated using MATLAB FFT in accordance with IEEE STD 519–2014 and shows a minimal harmonic distortion.