A high voltage stimulator for small electrode electrocutaneous stimulation

C. Poletto, C. Van Doren
{"title":"A high voltage stimulator for small electrode electrocutaneous stimulation","authors":"C. Poletto, C. Van Doren","doi":"10.1109/IEMBS.1997.756809","DOIUrl":null,"url":null,"abstract":"A high voltage stimulator has been designed to allow transcutaneous stimulation of tactile fibers of the fingertip. The output stage is based upon an improved Howland current pump topology, modified to allow high load impedances and small currents. The current output accuracy is better than 15% for 1 to 10 mA for 30 /spl mu/sec pulses. The rise time for square pulses is less than 2 /spl mu/sec. Common mode latch-up power supply problems are discussed.","PeriodicalId":342750,"journal":{"name":"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1997.756809","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

A high voltage stimulator has been designed to allow transcutaneous stimulation of tactile fibers of the fingertip. The output stage is based upon an improved Howland current pump topology, modified to allow high load impedances and small currents. The current output accuracy is better than 15% for 1 to 10 mA for 30 /spl mu/sec pulses. The rise time for square pulses is less than 2 /spl mu/sec. Common mode latch-up power supply problems are discussed.
一种用于小电极皮肤电刺激的高压刺激器
设计了一种高压刺激器,可以经皮刺激指尖的触觉纤维。输出级是基于改进的Howland电流泵拓扑,修改以允许高负载阻抗和小电流。对于30 /spl mu/sec脉冲,1至10 mA的电流输出精度优于15%。方形脉冲的上升时间小于2 /spl mu/sec。讨论了共模闭锁电源问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信