{"title":"Effect of Transformer Windings (Not Under The Test) on The Frequency Response (FR) of The Winding Under The Test","authors":"M. Gojiya, K. Badgujar","doi":"10.1109/ICERECT56837.2022.10059976","DOIUrl":null,"url":null,"abstract":"Sweep frequency response analysis (SFRA) is most conscious to changes in the electrical elements (R, L, C) related to the test setup and test object. Therefore, in order to monitor even the smallest winding movement in a transformer, SFRA testing is a very effective technique. The effect of changes in such electrical elements associated with the test setup (outside the test object) on the FR of the winding should be neglected. Similarly, the FR of the test object is affected by a factor located inside the transformer and unrelated to the test object. It is the transformer winding that is not being tested. All transformer windings are connected together. Even if one of the windings has a mechanical fault, it can interfere with the frequency response of the other healthy windings, even if it is not tested. In this article, experiment results are used to explore this idea.","PeriodicalId":205485,"journal":{"name":"2022 Fourth International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Fourth International Conference on Emerging Research in Electronics, Computer Science and Technology (ICERECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICERECT56837.2022.10059976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sweep frequency response analysis (SFRA) is most conscious to changes in the electrical elements (R, L, C) related to the test setup and test object. Therefore, in order to monitor even the smallest winding movement in a transformer, SFRA testing is a very effective technique. The effect of changes in such electrical elements associated with the test setup (outside the test object) on the FR of the winding should be neglected. Similarly, the FR of the test object is affected by a factor located inside the transformer and unrelated to the test object. It is the transformer winding that is not being tested. All transformer windings are connected together. Even if one of the windings has a mechanical fault, it can interfere with the frequency response of the other healthy windings, even if it is not tested. In this article, experiment results are used to explore this idea.
变压器绕组(非测试)对测试绕组频率响应(FR)的影响
扫描频响分析(SFRA)最关注与测试装置和测试对象相关的电气元件(R、L、C)的变化。因此,为了监测变压器中最小的绕组运动,SFRA测试是一种非常有效的技术。与测试装置(在测试对象之外)相关的这些电气元件的变化对绕组FR的影响应被忽略。类似地,测试对象的FR受到位于变压器内部且与测试对象无关的因素的影响。没有测试的是变压器绕组。所有的变压器绕组都连接在一起。即使其中一个绕组有机械故障,它也会干扰其他健康绕组的频率响应,即使它没有经过测试。本文用实验结果对这一思路进行了探讨。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信