Md. Ali Akbar, Swarup Chakraborty, Akib Jayed Islam, M. Farhad, Md. Manjurul Gani
{"title":"Performance Analysis of a Microstrip Patch Antenna for Biomedical Applications","authors":"Md. Ali Akbar, Swarup Chakraborty, Akib Jayed Islam, M. Farhad, Md. Manjurul Gani","doi":"10.1109/ECACE.2019.8679438","DOIUrl":null,"url":null,"abstract":"A microstrip patch antenna's design and performance analysis for biomedical applications which operating at 2.45 GHz frequency range in ISM Band (2.4 GHz to 2.5 GHz) is represented in this paper. The antenna's good-looking feature is the proper thickness and suitable dimension. The special feature of this antenna is to make it perfect for On-body matched biomedical applications. FR4 material is used as the substrate to design the antenna. Individual properties of the Phantom model are perfectly maintained to get proper software simulated result. All the simulations, calculations and parameter results are fit for on-body matched conditions. To design the antenna CST Microwave Studio is used. Impressive S11of more than −50 dB for off-body and on-body as well as Specific absorption rate (SAR) of 0.0005 W/kg in on-body make the antenna compatible for biomedical application.","PeriodicalId":226060,"journal":{"name":"2019 International Conference on Electrical, Computer and Communication Engineering (ECCE)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electrical, Computer and Communication Engineering (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECACE.2019.8679438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
A microstrip patch antenna's design and performance analysis for biomedical applications which operating at 2.45 GHz frequency range in ISM Band (2.4 GHz to 2.5 GHz) is represented in this paper. The antenna's good-looking feature is the proper thickness and suitable dimension. The special feature of this antenna is to make it perfect for On-body matched biomedical applications. FR4 material is used as the substrate to design the antenna. Individual properties of the Phantom model are perfectly maintained to get proper software simulated result. All the simulations, calculations and parameter results are fit for on-body matched conditions. To design the antenna CST Microwave Studio is used. Impressive S11of more than −50 dB for off-body and on-body as well as Specific absorption rate (SAR) of 0.0005 W/kg in on-body make the antenna compatible for biomedical application.