The wearable cardioverter-defibrillator in 2023: current evidence and clinical indications

J. Erath, R. Wakili
{"title":"The wearable cardioverter-defibrillator in 2023: current evidence and clinical indications","authors":"J. Erath, R. Wakili","doi":"10.26430/chungarica.2023.53.3.198","DOIUrl":null,"url":null,"abstract":"The wearable cardioverter-defibrillator (WCD) consists of a garment containing 3 self-gelling defibrillation patch electrodes, 2 on the back and 1 in the front, and 4 non-adhesive ECG electrodes connected to a monitoring unit (Figure 1). Worn around the chest like a vest, the WCD provides continuous ECG monitoring and automatically delivers up to 5 posterior-anterior defibrillation shocks per ventricular arrhythmia (VA) episode. The WCD proved to be both safe and effective in terminating ventricular tachyarrhythmia in various patient cohorts with primary or secondary prevention indication for sudden cardiac death. The first shock effectiveness varies from 91% in the earlier first-in-human studies to 100% in selected patients at-risk. The device is also able to transmit data via telemonitoring concerning arrhythmia and shock discharge, but also information on therapy compliance/adherence to wear the device. Further clinical information as daily heart rate, step count or cardiac acoustic biomarkers are collected that can potentially assist to monitor heart failure patients.","PeriodicalId":237121,"journal":{"name":"Cardiologia Hungarica","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiologia Hungarica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26430/chungarica.2023.53.3.198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The wearable cardioverter-defibrillator (WCD) consists of a garment containing 3 self-gelling defibrillation patch electrodes, 2 on the back and 1 in the front, and 4 non-adhesive ECG electrodes connected to a monitoring unit (Figure 1). Worn around the chest like a vest, the WCD provides continuous ECG monitoring and automatically delivers up to 5 posterior-anterior defibrillation shocks per ventricular arrhythmia (VA) episode. The WCD proved to be both safe and effective in terminating ventricular tachyarrhythmia in various patient cohorts with primary or secondary prevention indication for sudden cardiac death. The first shock effectiveness varies from 91% in the earlier first-in-human studies to 100% in selected patients at-risk. The device is also able to transmit data via telemonitoring concerning arrhythmia and shock discharge, but also information on therapy compliance/adherence to wear the device. Further clinical information as daily heart rate, step count or cardiac acoustic biomarkers are collected that can potentially assist to monitor heart failure patients.
2023年的可穿戴式心律转复除颤器:目前的证据和临床适应症
可穿戴式心律转复除颤器(WCD)由一件装有3个自凝胶除颤贴片电极的衣服组成,其中2个在背面,1个在前面,还有4个连接到监测单元的非粘附ECG电极(图1)。WCD像背心一样穿在胸前,提供连续的ECG监测,并在每次室性心律失常(VA)发作时自动提供多达5次后-前路除颤电击。在心脏性猝死一级或二级预防指征的不同患者队列中,WCD被证明是安全有效的终止室性心动过速。在早期的首次人体研究中,首次休克的有效性为91%,而在选定的高危患者中,首次休克的有效性为100%。该设备还能够通过远程监控传输有关心律失常和电击放电的数据,以及佩戴该设备的治疗依从性/依从性信息。进一步的临床信息,如每日心率,步数或心脏声学生物标志物收集可能有助于监测心力衰竭患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信