Optimal operation of Francis Small Hydro turbines with variabiable flow

R. Magureanu, M. Albu, V. Bostan, A. Dumitrescu, M. Pelizza, F. Andreea, G. Dimu, F. Popa, M. Rotaru
{"title":"Optimal operation of Francis Small Hydro turbines with variabiable flow","authors":"R. Magureanu, M. Albu, V. Bostan, A. Dumitrescu, M. Pelizza, F. Andreea, G. Dimu, F. Popa, M. Rotaru","doi":"10.1109/ISIE.2008.4677281","DOIUrl":null,"url":null,"abstract":"In this paper is presented a solution for optimal operation of the Francis turbine, the most used hydro energy converter in small hydro plants. As the efficiency of this turbine is highly dependent from the water flow, which generally has a large variation, variable speed operation was chosen. Due to the fact that all hydro generators are AC machines, the connection to the 50 Hz power grid can be done only using as interface the AC/DC DC/AC static converters. For higher than 1 MW power generators, front end three level inverters are recommended. In addition, for higher than 1 kV voltage, double three level inverters shall be used, as these are allowing their connection directly to the medium voltage grid, eliminating in this way the need of separation transformers. The converter control is done by a single chip DSP controller TM3202028, which takes care of all system functions.","PeriodicalId":262939,"journal":{"name":"2008 IEEE International Symposium on Industrial Electronics","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2008.4677281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

In this paper is presented a solution for optimal operation of the Francis turbine, the most used hydro energy converter in small hydro plants. As the efficiency of this turbine is highly dependent from the water flow, which generally has a large variation, variable speed operation was chosen. Due to the fact that all hydro generators are AC machines, the connection to the 50 Hz power grid can be done only using as interface the AC/DC DC/AC static converters. For higher than 1 MW power generators, front end three level inverters are recommended. In addition, for higher than 1 kV voltage, double three level inverters shall be used, as these are allowing their connection directly to the medium voltage grid, eliminating in this way the need of separation transformers. The converter control is done by a single chip DSP controller TM3202028, which takes care of all system functions.
变流量混流式小型水轮机的优化运行
本文提出了小型水电厂中最常用的水能转换器混流式水轮机的优化运行方案。由于水轮机的效率高度依赖于水流量,而水流量通常变化较大,因此选择了变速运行。由于所有水轮发电机都是交流机器,连接到50hz电网只能使用AC/DC DC/AC静态转换器作为接口。对于1mw以上的发电机,建议使用前端三电平逆变器。此外,对于高于1kv的电压,应使用双三电平逆变器,因为这些逆变器可以直接连接到中压电网,这样就不需要分离变压器了。转换器的控制由单片机DSP控制器TM3202028完成,负责系统的所有功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信