Raised floor computer data center: effect on rack inlet temperatures of chilled air exiting both the hot and cold aisles

R. Schmidt, E. Cruz
{"title":"Raised floor computer data center: effect on rack inlet temperatures of chilled air exiting both the hot and cold aisles","authors":"R. Schmidt, E. Cruz","doi":"10.1109/ITHERM.2002.1012507","DOIUrl":null,"url":null,"abstract":"This paper focuses on the effect of the rack inlet temperatures resulting from chilled air exhausting from perforated tiles situated in both the hot and cold aisles of a raised floor data center. Only the above floor (raised floor) flow and temperature distributions were analyzed for various flowrates exhausting from the perforated tiles. A Computational Fluid Dynamic(CFD) model was generated for the room with electronic equipment installed on a raised floor with particular focus on the effects on rack inlet temperatures of equipment heat load, placement of air conditioning (A/C) units and chilled air flowrates. Forty racks of data processing (DP) equipment were arranged in rows in a data center cooled by chilled air exhausting from perforated floor tiles. The chilled air was provided by four A/C units placed inside a room 12.1 m wide x 13.4 m long. Since the arrangement of the racks in the data center was symmetric only one-half of the data center needed to be modeled. The numerical modeling was performed using a commercially available finite control volume computer code called Flotherm (Trademark of Flomerics, Inc.). The flow was modeled using the k-e turbulence model. Results are displayed to provide some guidance on the design and layout of a data center.","PeriodicalId":299933,"journal":{"name":"ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"50","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.2002.1012507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 50

Abstract

This paper focuses on the effect of the rack inlet temperatures resulting from chilled air exhausting from perforated tiles situated in both the hot and cold aisles of a raised floor data center. Only the above floor (raised floor) flow and temperature distributions were analyzed for various flowrates exhausting from the perforated tiles. A Computational Fluid Dynamic(CFD) model was generated for the room with electronic equipment installed on a raised floor with particular focus on the effects on rack inlet temperatures of equipment heat load, placement of air conditioning (A/C) units and chilled air flowrates. Forty racks of data processing (DP) equipment were arranged in rows in a data center cooled by chilled air exhausting from perforated floor tiles. The chilled air was provided by four A/C units placed inside a room 12.1 m wide x 13.4 m long. Since the arrangement of the racks in the data center was symmetric only one-half of the data center needed to be modeled. The numerical modeling was performed using a commercially available finite control volume computer code called Flotherm (Trademark of Flomerics, Inc.). The flow was modeled using the k-e turbulence model. Results are displayed to provide some guidance on the design and layout of a data center.
架空地板计算机数据中心:冷热通道对机架入口空气温度的影响
本文主要研究架空地板数据中心冷热通道上的穿孔瓦排出的冷冻空气对机架入口温度的影响。仅分析了从穿孔砖排出的不同流量的上层(活动地板)的流动和温度分布。计算流体动力学(CFD)模型是为安装在活动地板上的电子设备的房间生成的,特别关注设备热负荷对机架入口温度、空调(A/C)单元的放置和冷却空气流量的影响。40个数据处理(DP)设备机架在一个数据中心内排成一排,通过从穿孔地砖排出的冷冻空气进行冷却。冷风由放置在12.1米宽、13.4米长的房间内的4台空调提供。由于数据中心中机架的排列是对称的,因此只需要对数据中心的一半进行建模。数值模拟是使用一种市售的有限控制体积计算机代码Flotherm (Flomerics, Inc.的商标)进行的。流动采用k-e湍流模型进行建模。结果显示,为数据中心的设计和布局提供一些指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信