Accuracy assessment phantom for surgical devices

Tapani Koivukangas, Jani P. A. Katisko
{"title":"Accuracy assessment phantom for surgical devices","authors":"Tapani Koivukangas, Jani P. A. Katisko","doi":"10.1109/CIBEC.2010.5716082","DOIUrl":null,"url":null,"abstract":"The objective of this study was to design and develop a phantom and an accuracy assessment protocol for surgical devices used at Oulu University Hospital, Oulu, Finland. The main criteria for this phantom were that it needed to be manufactured with sub-millimetric error between the calibration holes, easy to use and dimensionally suitable for MR scanners and an O-arm used at Oulu University Hospital. The designed phantom was used to assess the accuracy of the optical tracking and electromagnetic tracking system (EMTS) modalities of a commercial surgical navigator and the image quality of an O-arm. The studies showed that the design of the phantom fulfilled the requirements set for this study. The phantom functioned well and it was easy to use. It also had enough calibration holes to ascertain the trend of the accuracy and image errors. The present accuracy assessment protocol proved to be a practicable quality control tool for accuracy analysis in the hospital.","PeriodicalId":319141,"journal":{"name":"2010 5th Cairo International Biomedical Engineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 5th Cairo International Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIBEC.2010.5716082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The objective of this study was to design and develop a phantom and an accuracy assessment protocol for surgical devices used at Oulu University Hospital, Oulu, Finland. The main criteria for this phantom were that it needed to be manufactured with sub-millimetric error between the calibration holes, easy to use and dimensionally suitable for MR scanners and an O-arm used at Oulu University Hospital. The designed phantom was used to assess the accuracy of the optical tracking and electromagnetic tracking system (EMTS) modalities of a commercial surgical navigator and the image quality of an O-arm. The studies showed that the design of the phantom fulfilled the requirements set for this study. The phantom functioned well and it was easy to use. It also had enough calibration holes to ascertain the trend of the accuracy and image errors. The present accuracy assessment protocol proved to be a practicable quality control tool for accuracy analysis in the hospital.
外科器械精度评估模型
本研究的目的是为芬兰奥卢大学医院使用的手术器械设计和开发假体和准确性评估方案。该模型的主要标准是,它需要在校准孔之间以亚毫米误差制造,易于使用,尺寸适合于奥卢大学医院使用的MR扫描仪和o型臂。设计的假体用于评估商业外科导航仪的光学跟踪和电磁跟踪系统(EMTS)模式的准确性以及o型臂的图像质量。研究表明,该模型的设计满足了本研究的要求。“幻影”功能良好,使用方便。它还具有足够的校准孔,以确定精度和图像误差的趋势。该准确度评估方案是一种实用的准确度分析质量控制工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信