Thermal time response of microfilaments

R. Supino, J. Talghader
{"title":"Thermal time response of microfilaments","authors":"R. Supino, J. Talghader","doi":"10.1109/OMEMS.2000.879657","DOIUrl":null,"url":null,"abstract":"The thermal time response of polysilicon microfilaments has been characterized at high and room temperatures. We have found cool down time constants that are several times lower at room temperature than for equivalent filaments at high temperatures. It is proposed that the cool down transient can be directly controlled by \"substrate quenching,\" where the polysilicon filament is deflected into direct contact with the substrate. This could result in thermal responses several orders of magnitude faster than conventional structures and may have significant applications for high-speed microbolometer arrays.","PeriodicalId":148819,"journal":{"name":"2000 IEEE/LEOS International Conference on Optical MEMS (Cat. No.00EX399)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE/LEOS International Conference on Optical MEMS (Cat. No.00EX399)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2000.879657","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The thermal time response of polysilicon microfilaments has been characterized at high and room temperatures. We have found cool down time constants that are several times lower at room temperature than for equivalent filaments at high temperatures. It is proposed that the cool down transient can be directly controlled by "substrate quenching," where the polysilicon filament is deflected into direct contact with the substrate. This could result in thermal responses several orders of magnitude faster than conventional structures and may have significant applications for high-speed microbolometer arrays.
微丝的热时间响应
研究了多晶硅微丝在高温和室温下的热时间响应特性。我们发现室温下的冷却时间常数比高温下的等效细丝低几倍。有人提出,冷却瞬态可以通过“衬底淬火”直接控制,其中多晶硅灯丝偏转到与衬底直接接触。这可能导致热响应比传统结构快几个数量级,并且可能在高速微辐射热计阵列中有重要应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信