Benefits of Permanent Travel Measurement in High Voltage Circuit Breaker Online Monitoring

N. Gariboldi, Phillip L. Corliss
{"title":"Benefits of Permanent Travel Measurement in High Voltage Circuit Breaker Online Monitoring","authors":"N. Gariboldi, Phillip L. Corliss","doi":"10.1109/DIAGNOSTIKA.2018.8526036","DOIUrl":null,"url":null,"abstract":"The benefits of Condition Based Maintenance have been widely recognized for a long time. In recent years the focus shifted to its implementation. Since the resources for monitoring investments were not unlimited, the asset managers devoted their attention primarily on transformer monitoring at first, letting the condition monitoring of circuit breakers somehow fall behind (as evidenced in specific details from the CIGRE enquiry 2004-2007). Finally, circuit breakers are now getting more monitoring attention. In deciding which parameters should be kept under scrutiny to accurately assess the circuit breaker condition, travel measurement is one of the most discussed topics. Measuring the opening/closing coil current and the commutation of auxiliary contacts is essential, inexpensive and quite straightforward. Installing SF6 gas density monitoring, in addition to an already installed threshold gas relay, finds its motivation in environmental gas leakage regulations. The measurement of travel curves requires the permanent installation of a proper transducer and additional fitting work, which has an impact on the cost of the monitoring system. Supporting the best decision whether to go for it or not, the benefits in terms of monitoring assessment are analyzed in this paper. Starting from the influence of contact travel on circuit breaker performance, typical parameters that can be derived from this measurement are analyzed and compared in relation to possible circuit breaker problems. Considerations are provided as to where to take the movement from and how to rescale the input signal. Some indications are also given on how to select a proper travel transducer and DC/DC converter power supply, what to pay attention to from an electrical as well as from a mechanical point of view to enhance reliability and measurement accuracy.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The benefits of Condition Based Maintenance have been widely recognized for a long time. In recent years the focus shifted to its implementation. Since the resources for monitoring investments were not unlimited, the asset managers devoted their attention primarily on transformer monitoring at first, letting the condition monitoring of circuit breakers somehow fall behind (as evidenced in specific details from the CIGRE enquiry 2004-2007). Finally, circuit breakers are now getting more monitoring attention. In deciding which parameters should be kept under scrutiny to accurately assess the circuit breaker condition, travel measurement is one of the most discussed topics. Measuring the opening/closing coil current and the commutation of auxiliary contacts is essential, inexpensive and quite straightforward. Installing SF6 gas density monitoring, in addition to an already installed threshold gas relay, finds its motivation in environmental gas leakage regulations. The measurement of travel curves requires the permanent installation of a proper transducer and additional fitting work, which has an impact on the cost of the monitoring system. Supporting the best decision whether to go for it or not, the benefits in terms of monitoring assessment are analyzed in this paper. Starting from the influence of contact travel on circuit breaker performance, typical parameters that can be derived from this measurement are analyzed and compared in relation to possible circuit breaker problems. Considerations are provided as to where to take the movement from and how to rescale the input signal. Some indications are also given on how to select a proper travel transducer and DC/DC converter power supply, what to pay attention to from an electrical as well as from a mechanical point of view to enhance reliability and measurement accuracy.
永久行程测量在高压断路器在线监测中的好处
长期以来,基于状态的维修的好处已得到广泛认可。近年来,重点转移到其实施上。由于监测投资的资源不是无限的,资产管理公司一开始主要把注意力放在变压器监测上,让断路器的状态监测在某种程度上落后了(2004-2007年CIGRE调查的具体细节证明了这一点)。最后,断路器现在得到了更多的监控关注。为了准确地评估断路器的状态,行程测量是讨论最多的问题之一。测量开/闭线圈电流和辅助触点的换流是必不可少的,便宜且相当直接。除了已经安装的阈值气体继电器外,安装SF6气体密度监测的动机是环境气体泄漏法规。行程曲线的测量需要永久安装合适的换能器和额外的装配工作,这对监测系统的成本有影响。本文从监测评价的角度对效益进行了分析,以支持是否进行监测的最佳决策。从触点行程对断路器性能的影响出发,针对断路器可能出现的问题,对该测量得出的典型参数进行分析和比较。考虑到从哪里移动以及如何重新调整输入信号。本文还就如何选择合适的行程传感器和DC/DC转换器电源,从电气和机械角度提高可靠性和测量精度应注意的事项给出了一些指示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信