{"title":"Modification of waveguide flange design for millimeter and submillimeter-wave measurements","authors":"M. Horibe, K. Noda","doi":"10.1109/ARFTG77.2011.6034557","DOIUrl":null,"url":null,"abstract":"Waveguide flange design makes major impact to measurement reproducibility in the range of millimeter and sub-millimeter-wave frequencies, e.g. above 110 GHz. Original concept of flange design, so-call “Oshima” flange, was established in the early 2000s. Its flange alignment is ensured using ring with tight tolerance, however, it is not compatible to MIL-DTL-3922/67C (UG-387) flange. This paper describes a modification of “Oshima” flange in order to establishing a compatibility with UG-387 flange design, and evaluation result of its capability of connection repeatability in the WR-3 (220 GHz–330 GHz) frequency band. Furthermore, the quarter wave length shim, as a TRL “through” line standard, is specially modified to fit with a new design of “Oshima” flange, then, its capability of connection repeatability is also measured and discussed.","PeriodicalId":257372,"journal":{"name":"77th ARFTG Microwave Measurement Conference","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"77th ARFTG Microwave Measurement Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG77.2011.6034557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25
Abstract
Waveguide flange design makes major impact to measurement reproducibility in the range of millimeter and sub-millimeter-wave frequencies, e.g. above 110 GHz. Original concept of flange design, so-call “Oshima” flange, was established in the early 2000s. Its flange alignment is ensured using ring with tight tolerance, however, it is not compatible to MIL-DTL-3922/67C (UG-387) flange. This paper describes a modification of “Oshima” flange in order to establishing a compatibility with UG-387 flange design, and evaluation result of its capability of connection repeatability in the WR-3 (220 GHz–330 GHz) frequency band. Furthermore, the quarter wave length shim, as a TRL “through” line standard, is specially modified to fit with a new design of “Oshima” flange, then, its capability of connection repeatability is also measured and discussed.