Dynamic control and performance of an isolated dual-active-bridge DC–DC converter

Kazuto Takagi, H. Fujita
{"title":"Dynamic control and performance of an isolated dual-active-bridge DC–DC converter","authors":"Kazuto Takagi, H. Fujita","doi":"10.1109/ICPE.2015.7167980","DOIUrl":null,"url":null,"abstract":"This paper presents dynamic analysis and control of an isolated dual-active-bridge (DAB) dc-dc converter. Conventional control methods of the DAB converter may cause dc offsets in both inductor current and transformer magnetizing current in transient states. The dc offset in the inductor current introduces an excessive peak current through the switching devices. The dc offset in the magnetizing current cannot be neglected and may induce magnetic flux saturation. Conventional phase-shift control methods simultaneously turn on and off the diagonal switches in each H-bridge to produce a square-wave voltage. On the other hand, the proposed method independently controls diagonal switches to generate short zero-voltage periods in a transient state. The theoretical analysis derives the requirements of the switching angles, which enable both inductor and magnetizing currents to be settled within a half switching period without any dc offset. A 5-kW experimental system verifies the validity of the proposed control method.","PeriodicalId":160988,"journal":{"name":"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPE.2015.7167980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

This paper presents dynamic analysis and control of an isolated dual-active-bridge (DAB) dc-dc converter. Conventional control methods of the DAB converter may cause dc offsets in both inductor current and transformer magnetizing current in transient states. The dc offset in the inductor current introduces an excessive peak current through the switching devices. The dc offset in the magnetizing current cannot be neglected and may induce magnetic flux saturation. Conventional phase-shift control methods simultaneously turn on and off the diagonal switches in each H-bridge to produce a square-wave voltage. On the other hand, the proposed method independently controls diagonal switches to generate short zero-voltage periods in a transient state. The theoretical analysis derives the requirements of the switching angles, which enable both inductor and magnetizing currents to be settled within a half switching period without any dc offset. A 5-kW experimental system verifies the validity of the proposed control method.
隔离型双有源桥式DC-DC变换器的动态控制与性能
本文介绍了隔离式双有源桥式(DAB) dc-dc变换器的动态分析与控制。传统的DAB变换器控制方法会造成电感电流和变压器暂态磁化电流的直流偏置。电感电流中的直流偏置通过开关器件引入了一个过高的峰值电流。磁化电流中的直流偏置不可忽略,可能引起磁通饱和。传统的相移控制方法同时打开和关闭每个h桥中的对角开关以产生方波电压。另一方面,该方法独立控制对角开关在瞬态下产生短的零电压周期。理论分析得出了开关角的要求,使电感电流和磁化电流在半开关周期内都能稳定下来,而不产生直流偏置。一个5kw的实验系统验证了所提控制方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信