Imbalance Power Sharing Improvement in Autonomous Microgrids Consisting of Grid-Feeding and Grid-Supporting Inverters

M. Karimi, S. A. Taher, Z. D. Arani, J. Guerrero
{"title":"Imbalance Power Sharing Improvement in Autonomous Microgrids Consisting of Grid-Feeding and Grid-Supporting Inverters","authors":"M. Karimi, S. A. Taher, Z. D. Arani, J. Guerrero","doi":"10.1109/IWEC52400.2021.9466976","DOIUrl":null,"url":null,"abstract":"Imbalance power sharing problem in autonomous AC microgrids (MGs) is usually addressed by inverter-interfaced distributed generation units (IIDGs) with reliable DC power supply operating in voltage control mode (VCM); while IIDGs with unpredictable DC source (i.e. solar, wind, etc.) are rarely considered as a potential origin of contribution. This paper introduces an imbalance power sharing role for such units considering that they are usually generating intermittent, unreliable, and erratic power. To cope with the problem, negative virtual impedance and voltage unbalanced factor (VUF) concepts are used and applied to an autonomous inverter- interfaced MG, including two grid-supporting battery energy storage systems (BESSs) and a grid-feeding photovoltaic (PV) system. Specifically, a proportion of negative-sequence output current is added to the control structure of grid-feeding PV system which is obtained from the product of output current and VUF transformed into the synchronous reference frame with negative fundamental frequency. This strategy enables us to use the remaining capacity of a PV system for imbalance power compensation. Moreover, proper reactive power sharing between grid-supporting BESSs is achieved using virtual impedance strategy. Simulation studies conducted in MATLAB/SIMULINK software verify the excellent performance of the proposed approach in improving imbalance power sharing amongst IIDGs. Furthermore, the VUF values at IIDG outputs are kept less than the maximum allowable amount of 3%.","PeriodicalId":281528,"journal":{"name":"7th Iran Wind Energy Conference (IWEC2021)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"7th Iran Wind Energy Conference (IWEC2021)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWEC52400.2021.9466976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Imbalance power sharing problem in autonomous AC microgrids (MGs) is usually addressed by inverter-interfaced distributed generation units (IIDGs) with reliable DC power supply operating in voltage control mode (VCM); while IIDGs with unpredictable DC source (i.e. solar, wind, etc.) are rarely considered as a potential origin of contribution. This paper introduces an imbalance power sharing role for such units considering that they are usually generating intermittent, unreliable, and erratic power. To cope with the problem, negative virtual impedance and voltage unbalanced factor (VUF) concepts are used and applied to an autonomous inverter- interfaced MG, including two grid-supporting battery energy storage systems (BESSs) and a grid-feeding photovoltaic (PV) system. Specifically, a proportion of negative-sequence output current is added to the control structure of grid-feeding PV system which is obtained from the product of output current and VUF transformed into the synchronous reference frame with negative fundamental frequency. This strategy enables us to use the remaining capacity of a PV system for imbalance power compensation. Moreover, proper reactive power sharing between grid-supporting BESSs is achieved using virtual impedance strategy. Simulation studies conducted in MATLAB/SIMULINK software verify the excellent performance of the proposed approach in improving imbalance power sharing amongst IIDGs. Furthermore, the VUF values at IIDG outputs are kept less than the maximum allowable amount of 3%.
由馈网逆变器和并网逆变器组成的自治微电网的不平衡电力共享改进
自治交流微电网的电力分配不平衡问题通常由逆变器接口的分布式发电机组(iidg)解决,该机组具有可靠的直流电源,运行在电压控制模式(VCM)下;而具有不可预测直流源(即太阳能、风能等)的iidg很少被认为是潜在的贡献来源。考虑到此类机组通常产生间歇性、不可靠和不稳定的电力,本文引入了不平衡功率分担作用。为了解决这一问题,采用负虚拟阻抗和电压不平衡因子(VUF)概念,并将其应用于自主逆变器接口的MG,包括两个支持电网的电池储能系统(bess)和一个并网光伏(PV)系统。具体而言,在并网光伏系统的控制结构中加入负序输出电流的比例,该比例由输出电流与VUF的乘积变换到负基频的同步参考系中得到。该策略使我们能够利用光伏系统的剩余容量进行不平衡功率补偿。此外,采用虚拟阻抗策略实现了并网bess之间的合理无功分担。在MATLAB/SIMULINK软件中进行的仿真研究验证了该方法在改善iidg间功率分配不平衡方面的优异性能。此外,在IIDG输出处的VUF值保持小于最大允许量的3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书