N. Jaeger, C. Jaeger, H. Kato, F. Rahmatian, S. Cherukupalli, A. J. Vandermaar, G. S. Polovick
{"title":"An on-line real-time relative dissipation factor monitoring system","authors":"N. Jaeger, C. Jaeger, H. Kato, F. Rahmatian, S. Cherukupalli, A. J. Vandermaar, G. S. Polovick","doi":"10.1109/CCECE.1998.685541","DOIUrl":null,"url":null,"abstract":"A prototype on-line, real-time relative dissipation factor system is described. Selected data recorded during a long-term, more than a year, experiment, conducted in a high-voltage laboratory, is presented. Data taken on \"good\" current transformers, data indicating the resolution of the system, and data taken during the actual failure of a current transformer are presented. The data presented illustrate the potential for on-line, real-time relative dissipation factor monitoring of fluid-paper insulation systems to help utilities maximize their use of capital intensive assets and reduce the risk of disruptive failures.","PeriodicalId":177613,"journal":{"name":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.1998.685541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A prototype on-line, real-time relative dissipation factor system is described. Selected data recorded during a long-term, more than a year, experiment, conducted in a high-voltage laboratory, is presented. Data taken on "good" current transformers, data indicating the resolution of the system, and data taken during the actual failure of a current transformer are presented. The data presented illustrate the potential for on-line, real-time relative dissipation factor monitoring of fluid-paper insulation systems to help utilities maximize their use of capital intensive assets and reduce the risk of disruptive failures.