Çocuklarda, Ergenlerde ve Genç Yetişkinlerde Transtorasik Ekokardiyografi ve Floroskopi Kılavuzluğunda Cihazla Transkateter Atriyal Septal Defekt Kapatılması

Ahmet Vedat Kavurt, Emine Gulsah Torun, Ayben Kiliç, Denizhan Bağrul, A. Gürsu, İ̇brahim Ece, İbrahim Çetin
{"title":"Çocuklarda, Ergenlerde ve Genç Yetişkinlerde Transtorasik Ekokardiyografi ve Floroskopi Kılavuzluğunda Cihazla Transkateter Atriyal Septal Defekt Kapatılması","authors":"Ahmet Vedat Kavurt, Emine Gulsah Torun, Ayben Kiliç, Denizhan Bağrul, A. Gürsu, İ̇brahim Ece, İbrahim Çetin","doi":"10.12956/tchd.1143186","DOIUrl":null,"url":null,"abstract":"Objective: The aim of this study was to evaluate the safety and efficacy of transcatheter atrial septal defect (ASD) closure guided by fluoroscopy and transthoracic echocardiography (TTE) and to present our experiences. Material and Methods: In this study, we evaluated 108 patients’ files taken to the catheter laboratory for transcatheter ASD closure retrospectively. The procedure was abandoned in ten patients because of septum device disproportion (6) and deficient rims (4), mainly inferior vena cava rim.\nResults: Transcatheter ASD closure guided by TTE was performed in 98 patients (59 female). The mean age of patients was 9.5±6 years (2.6-46), and the mean weight was 30.3±15.3kg (12-80). TTE-guided ASD closure was successfully performed in 92 of 98 (94%) patients. The median largest ASD diameter measured by TTE was 10.75 mm (interquartile range (IQR) 9.12-14. The median stretched balloon diameter measured by fluoroscopy was 14 mm (IQR 12.4-18). The median device waist diameter was 14 mm (IQR 13-18), the median device left atrial (LA) disk diameter was 28 mm (IQR 26-31), and the median ratio of LA disc diameter to total septal diameter was 75% (IQR 68-81). The median fluoroscopy and procedural times were 8 minutes (IQR 5.6-13.75) and 36.5 minutes (IQR 30-49) respectively.\nConclusion: Transcatheter ASD closure guided by TTE and fluoroscopy is safe and effective in children, adolescents, and young adults.","PeriodicalId":246612,"journal":{"name":"Turkish Journal of Pediatric Disease","volume":"239 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Pediatric Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12956/tchd.1143186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this study was to evaluate the safety and efficacy of transcatheter atrial septal defect (ASD) closure guided by fluoroscopy and transthoracic echocardiography (TTE) and to present our experiences. Material and Methods: In this study, we evaluated 108 patients’ files taken to the catheter laboratory for transcatheter ASD closure retrospectively. The procedure was abandoned in ten patients because of septum device disproportion (6) and deficient rims (4), mainly inferior vena cava rim. Results: Transcatheter ASD closure guided by TTE was performed in 98 patients (59 female). The mean age of patients was 9.5±6 years (2.6-46), and the mean weight was 30.3±15.3kg (12-80). TTE-guided ASD closure was successfully performed in 92 of 98 (94%) patients. The median largest ASD diameter measured by TTE was 10.75 mm (interquartile range (IQR) 9.12-14. The median stretched balloon diameter measured by fluoroscopy was 14 mm (IQR 12.4-18). The median device waist diameter was 14 mm (IQR 13-18), the median device left atrial (LA) disk diameter was 28 mm (IQR 26-31), and the median ratio of LA disc diameter to total septal diameter was 75% (IQR 68-81). The median fluoroscopy and procedural times were 8 minutes (IQR 5.6-13.75) and 36.5 minutes (IQR 30-49) respectively. Conclusion: Transcatheter ASD closure guided by TTE and fluoroscopy is safe and effective in children, adolescents, and young adults.
目的:评价透视和经胸超声心动图(TTE)引导下经导管房间隔缺损(ASD)闭合的安全性和有效性,并提出我们的经验。材料与方法:本研究回顾性分析108例经导管ASD闭锁患者的资料。10例患者因中隔装置比例失调(6例)和边缘缺陷(4例)(主要是下腔静脉边缘)而放弃该手术。结果:行TTE引导下经导管ASD闭合术98例,其中女性59例。患者平均年龄9.5±6岁(2.6 ~ 46岁),平均体重30.3±15.3kg(12 ~ 80岁)。98例患者中有92例(94%)成功完成了te引导的ASD闭合。TTE测量的ASD直径中位数最大为10.75 mm(四分位间距(IQR) 9.12-14)。透视测得中位拉伸球囊直径为14 mm (IQR 12.4-18)。中位装置腰径为14 mm (IQR 13-18),中位装置左房(LA)盘径为28 mm (IQR 26-31),左房盘径与间隔总直径的中位比值为75% (IQR 68-81)。中位透视时间和手术时间分别为8分钟(IQR 5.6-13.75)和36.5分钟(IQR 30-49)。结论:TTE和透视引导下的经导管ASD闭合术对儿童、青少年和青壮年是安全有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信