Inspection of short fault in power-plane with irregular and perforated shapes [MCMs]

F. Chao, R. Wu
{"title":"Inspection of short fault in power-plane with irregular and perforated shapes [MCMs]","authors":"F. Chao, R. Wu","doi":"10.1109/IEMT.1995.526110","DOIUrl":null,"url":null,"abstract":"The inspection of short fault in the power plane with irregular and perforated shapes is discussed in this study. Finite element method is utilized in calculating the normalized potential distribution of an irregular and perforated plane. Current source is applied on two diagonal corners of the power plane. The desired short fault position is then determined by the intersection of two zero voltage contour lines obtained in two different test setups. The short fault can be determined by as few as four measurements. The current driving points are also utilized as voltage sensing points. Although the accuracy is not as good as internal measurements, it can provide a convenient way for quick estimation.","PeriodicalId":123707,"journal":{"name":"Seventeenth IEEE/CPMT International Electronics Manufacturing Technology Symposium. 'Manufacturing Technologies - Present and Future'","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seventeenth IEEE/CPMT International Electronics Manufacturing Technology Symposium. 'Manufacturing Technologies - Present and Future'","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMT.1995.526110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The inspection of short fault in the power plane with irregular and perforated shapes is discussed in this study. Finite element method is utilized in calculating the normalized potential distribution of an irregular and perforated plane. Current source is applied on two diagonal corners of the power plane. The desired short fault position is then determined by the intersection of two zero voltage contour lines obtained in two different test setups. The short fault can be determined by as few as four measurements. The current driving points are also utilized as voltage sensing points. Although the accuracy is not as good as internal measurements, it can provide a convenient way for quick estimation.
不规则和穿孔动力平面短故障的检测
本文讨论了带不规则和穿孔形状的动力平面短故障的检测方法。采用有限元法计算了不规则穿孔平面的归一化电位分布。电流源施加在电源平面的两个对角角上。然后通过在两个不同的测试装置中获得的两条零电压轮廓线的交集来确定所需的短故障位置。短故障只需四次测量就能确定。电流驱动点也用作电压感测点。虽然精度不如内部测量,但它可以为快速估计提供一种方便的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信