Study on Counter-flow Air to Air Heat Exchange for Air Handling Unit of Smart Buildings

V. Nicolau, M. Andrei, G. Petrea
{"title":"Study on Counter-flow Air to Air Heat Exchange for Air Handling Unit of Smart Buildings","authors":"V. Nicolau, M. Andrei, G. Petrea","doi":"10.1109/SIITME53254.2021.9663600","DOIUrl":null,"url":null,"abstract":"Minimizing the energy consumption is a major factor for all smart buildings. As a result, heat exchangers are used for energy recovery. The simplest heat exchanger is tube-in-tube type, in which the counter-flow type is the most efficient. In this paper, counter-flow air to air heat exchanger is studied, using a lab scale model. Four temperature-humidity sensors are used to measure the input and output parameters for every end of each tube. The performance of heat exchanger is analyzed by means of experimental results. Different values of inlet temperature and humidity of hot air flow are applied, and spatial and temporal variable distributions are analyzed. The efficiency of heat exchanger can be observed even for small steps of inlet values.","PeriodicalId":426485,"journal":{"name":"2021 IEEE 27th International Symposium for Design and Technology in Electronic Packaging (SIITME)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 27th International Symposium for Design and Technology in Electronic Packaging (SIITME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIITME53254.2021.9663600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Minimizing the energy consumption is a major factor for all smart buildings. As a result, heat exchangers are used for energy recovery. The simplest heat exchanger is tube-in-tube type, in which the counter-flow type is the most efficient. In this paper, counter-flow air to air heat exchanger is studied, using a lab scale model. Four temperature-humidity sensors are used to measure the input and output parameters for every end of each tube. The performance of heat exchanger is analyzed by means of experimental results. Different values of inlet temperature and humidity of hot air flow are applied, and spatial and temporal variable distributions are analyzed. The efficiency of heat exchanger can be observed even for small steps of inlet values.
智能建筑空气处理机组反流式空气换热研究
最小化能源消耗是所有智能建筑的主要因素。因此,热交换器被用于能量回收。最简单的换热器是管中管式换热器,其中逆流式换热器效率最高。本文采用实验室模型对逆流式空气-空气换热器进行了研究。4个温湿度传感器用于测量每根管子两端的输入和输出参数。通过实验结果对换热器的性能进行了分析。采用不同的热风入口温度和湿度值,分析了热风入口温度和湿度的时空变量分布。热交换器的效率甚至可以观察到入口值的微小变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信