Cooling and/or heating of an equipment room without using any freon, no maintenance and almost no consumption of energy

R. Ulfvengren, A. Johansson, M. Klang
{"title":"Cooling and/or heating of an equipment room without using any freon, no maintenance and almost no consumption of energy","authors":"R. Ulfvengren, A. Johansson, M. Klang","doi":"10.1109/INTLEC.1994.396653","DOIUrl":null,"url":null,"abstract":"For a long time the praxis has been, that tele-equipment should have a very narrow temperature range when being installed into an equipment room, maybe only a few degrees between the highest and lowest temperature. However, by the new technology that has come out in this field, it has been proved that the temperature can easily vary from in some cases 5/spl deg/C to 35/spl deg/C. This means, that in many telecommunication rooms today, the overheating coming from the equipment is taken away daytime and in many cases the room has to be heated at nighttime. This is waste of energy and it also makes the installation very complicated and expensive. To find a system, which can for example store the cold of the night and use that as a cooling media at daytime and vice versa, would be favourable. The authors describe the development and testing of the Heat Pac concept, which is based on phase change material heat storage, to meet these conditions.<<ETX>>","PeriodicalId":123164,"journal":{"name":"Proceedings of Intelec 94","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Intelec 94","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1994.396653","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

For a long time the praxis has been, that tele-equipment should have a very narrow temperature range when being installed into an equipment room, maybe only a few degrees between the highest and lowest temperature. However, by the new technology that has come out in this field, it has been proved that the temperature can easily vary from in some cases 5/spl deg/C to 35/spl deg/C. This means, that in many telecommunication rooms today, the overheating coming from the equipment is taken away daytime and in many cases the room has to be heated at nighttime. This is waste of energy and it also makes the installation very complicated and expensive. To find a system, which can for example store the cold of the night and use that as a cooling media at daytime and vice versa, would be favourable. The authors describe the development and testing of the Heat Pac concept, which is based on phase change material heat storage, to meet these conditions.<>
在不使用任何氟利昂的情况下冷却和/或加热机房,无需维护,几乎不消耗能源
长期以来,远程设备安装在机房内的温度范围很窄,最高温度和最低温度之间可能只有几度。然而,通过该领域出现的新技术,已经证明温度在某些情况下可以很容易地从5/spl℃变化到35/spl℃。这意味着,在今天的许多电信房间里,设备产生的过热现象在白天被消除,在许多情况下,房间必须在夜间加热。这是对能源的浪费,也使安装变得非常复杂和昂贵。找到一种系统,例如,它可以储存夜间的寒冷,并在白天将其用作冷却介质,反之亦然,将是有利的。作者描述了基于相变材料储热的Heat Pac概念的开发和测试,以满足这些条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信