Nondestructive Testing of Cable Ducts in Concrete Columns and Walls Using the Impact-Echo Method

J. S. Clausen, A. Knudsen
{"title":"Nondestructive Testing of Cable Ducts in Concrete Columns and Walls Using the Impact-Echo Method","authors":"J. S. Clausen, A. Knudsen","doi":"10.14359/51663215","DOIUrl":null,"url":null,"abstract":"This paper describes how the appearance of cracks and spalling in concrete columns in a new eight-story office building brought about concerns that the injection of the ducts in the columns was of poor quality. The cracks were mainly present at one floor, and trial drillings into the ducts on columns with severe cracks disclosed the presence of water and loose gravel and aggregates. Opening a duct revealed that the duct was either partially empty, filled with compacted gravel, or fully grouted. It was decided to use the impact-echo (IE) method to investigate the columns and ducts. Each column contains four ducts with a 25 mm (1 in.) diameter reinforcing bar for distribution of the shear stress at the lower and upper 1.0 m (3 ft) to each floor. Testing was performed for each 0.1 m (4 in.) elevation in these areas. The criterion to approve the injection was that at least 0.7 m (2 ft) of the column at the floor or the ceiling was fully injected. After testing the columns on 3 floors, it was decided to investigate the ducts in the walls of the three stairwells of the building, as they were vital for transferring the stresses of the reinforcement down through the building. Verification of the IE-system by drilling cores showed that is possible to distinguish between empty ducts, fully injected ducts, and ducts with compacted gravel. More than 35,000 measurements were made. The examination of the ducts showed that approximately 63% of tests at the top and approximately 86% at the bottom of the columns and walls indicated full injection.","PeriodicalId":232163,"journal":{"name":"SP-261: 10th ACI International Conference on Recent Advances in Concrete Technology and Sustainability Issues","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-261: 10th ACI International Conference on Recent Advances in Concrete Technology and Sustainability Issues","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/51663215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes how the appearance of cracks and spalling in concrete columns in a new eight-story office building brought about concerns that the injection of the ducts in the columns was of poor quality. The cracks were mainly present at one floor, and trial drillings into the ducts on columns with severe cracks disclosed the presence of water and loose gravel and aggregates. Opening a duct revealed that the duct was either partially empty, filled with compacted gravel, or fully grouted. It was decided to use the impact-echo (IE) method to investigate the columns and ducts. Each column contains four ducts with a 25 mm (1 in.) diameter reinforcing bar for distribution of the shear stress at the lower and upper 1.0 m (3 ft) to each floor. Testing was performed for each 0.1 m (4 in.) elevation in these areas. The criterion to approve the injection was that at least 0.7 m (2 ft) of the column at the floor or the ceiling was fully injected. After testing the columns on 3 floors, it was decided to investigate the ducts in the walls of the three stairwells of the building, as they were vital for transferring the stresses of the reinforcement down through the building. Verification of the IE-system by drilling cores showed that is possible to distinguish between empty ducts, fully injected ducts, and ducts with compacted gravel. More than 35,000 measurements were made. The examination of the ducts showed that approximately 63% of tests at the top and approximately 86% at the bottom of the columns and walls indicated full injection.
冲击回波法在混凝土柱墙电缆管道无损检测中的应用
本文描述了一座新建的八层办公楼的混凝土柱出现裂缝和剥落,引起人们对柱中管道注入质量差的担忧。裂缝主要出现在一层,在有严重裂缝的柱上的管道上进行试钻,发现存在水和松散的砾石和骨料。打开管道,发现管道要么是部分空的,要么是填满了压实的砾石,要么是完全灌浆的。决定采用冲击回波法(IE)对立柱和导管进行调查。每根柱子包含四根直径为25mm(1英寸)的钢筋,用于分配每层1.0 m(3英尺)上下的剪应力。在这些区域,每升高0.1 m(4英寸)进行测试。批准注入的标准是,至少有0.7米(2英尺)的柱在地板或天花板上被完全注入。在测试了三层楼的柱子后,决定调查建筑三个楼梯间墙壁上的管道,因为它们对于将加固的应力传递到建筑中至关重要。通过钻取岩心验证的ie系统表明,可以区分空管道、完全注入管道和砾石压实的管道。总共进行了35000多次测量。对管道的检查表明,在柱和壁的顶部约63%的测试和底部约86%的测试表明充分注入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信