{"title":"Online precision gas evaluation of the ATLAS Muon Spectrometer during LHC Run1","authors":"C. Geng","doi":"10.1109/NSSMIC.2014.7431058","DOIUrl":null,"url":null,"abstract":"The ATLAS Muon Spectrometer, a six story structure embedded in a toroidal magnetic field, is constructed of nearly 1200 Monitored Drift Tube chambers (MDTs) containing 354,000 aluminum drift tubes. The operating gas is 93% Ar + 7% CO2 with a small amount of water vapor at a pressure of 3 bar. The momentum resolution required for ATLAS physics demands that MDT gas quality and the associated gas dependent calibrations be determined with a rapid feedback cycle. During the LHC Run1, more than 2 billion liters of gas flowed through the detector at a rate 100,000 l/hr. Online evaluation of MDT gas in real time and the associated contribution to the determination of the time-to-space functions was conducted by the dedicated Gas Monitor Chamber (GMC). We report on the operation and results of the GMC over the first three years of LHC running. During this period, the GMC has operated with a nearly 100% duty cycle, providing hourly measurements of the MDT drift times with 1 ns precision, corresponding to minute changes in gas composition.","PeriodicalId":144711,"journal":{"name":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2014.7431058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The ATLAS Muon Spectrometer, a six story structure embedded in a toroidal magnetic field, is constructed of nearly 1200 Monitored Drift Tube chambers (MDTs) containing 354,000 aluminum drift tubes. The operating gas is 93% Ar + 7% CO2 with a small amount of water vapor at a pressure of 3 bar. The momentum resolution required for ATLAS physics demands that MDT gas quality and the associated gas dependent calibrations be determined with a rapid feedback cycle. During the LHC Run1, more than 2 billion liters of gas flowed through the detector at a rate 100,000 l/hr. Online evaluation of MDT gas in real time and the associated contribution to the determination of the time-to-space functions was conducted by the dedicated Gas Monitor Chamber (GMC). We report on the operation and results of the GMC over the first three years of LHC running. During this period, the GMC has operated with a nearly 100% duty cycle, providing hourly measurements of the MDT drift times with 1 ns precision, corresponding to minute changes in gas composition.
大型强子对撞机运行过程中ATLAS μ子谱仪的在线精密气体评价
ATLAS μ子光谱仪是一个嵌入环形磁场的六层结构,由近1200个监测漂移管室(mdt)组成,其中包含354,000个铝漂移管。工作气体为93% Ar + 7% CO2,加上少量水蒸气,压力为3bar。ATLAS物理所需的动量分辨率要求MDT气体质量和相关气体依赖的校准以快速反馈周期确定。在大型强子对撞机运行期间,超过20亿升的气体以每小时10万升的速度流过探测器。通过专用气体监测室(GMC)对MDT气体进行实时在线评估,并确定相关的时空函数贡献。我们报告了大型强子对撞机运行前三年GMC的运行情况和结果。在此期间,GMC以接近100%的占空比运行,以1ns的精度提供MDT漂移时间的每小时测量,对应于气体成分的微小变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信