Performance of a 512/spl times/3 pixel microbolometer detector for space imaging applications

T. Pope, C. Alain, L. L. Noc, H. Jerominek, L. Phong, W. Zheng
{"title":"Performance of a 512/spl times/3 pixel microbolometer detector for space imaging applications","authors":"T. Pope, C. Alain, L. L. Noc, H. Jerominek, L. Phong, W. Zheng","doi":"10.1109/ICMENS.2005.98","DOIUrl":null,"url":null,"abstract":"A 512/spl times/3 pixel microbolometer detector array has been developed for space imaging applications. Each pixel includes thermally sensitive and reference microbolometer detectors fabricated by surface micromachining and arranged in a Wheatstone bridge configuration. The detector array is sensitive to thermal infrared radiation and early characterisation shows good uniformity of response between the three lines and among pixels in a given line. The pixel bridge configuration reduces the impact of die temperature drift on pixel output to approximately 40 /spl mu/V/K, a three hundred fold improvement over a single microbolometer detector.","PeriodicalId":185824,"journal":{"name":"2005 International Conference on MEMS,NANO and Smart Systems","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Conference on MEMS,NANO and Smart Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMENS.2005.98","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A 512/spl times/3 pixel microbolometer detector array has been developed for space imaging applications. Each pixel includes thermally sensitive and reference microbolometer detectors fabricated by surface micromachining and arranged in a Wheatstone bridge configuration. The detector array is sensitive to thermal infrared radiation and early characterisation shows good uniformity of response between the three lines and among pixels in a given line. The pixel bridge configuration reduces the impact of die temperature drift on pixel output to approximately 40 /spl mu/V/K, a three hundred fold improvement over a single microbolometer detector.
用于空间成像应用的512/spl倍/3像素微辐射热计探测器的性能
研制了一种用于空间成像的512/spl倍/3像素微辐射热计探测器阵列。每个像素包括热敏和参考微辐射热计探测器制造的表面微加工,并安排在惠斯通电桥配置。探测器阵列对热红外辐射敏感,早期表征表明三线之间和给定线内像素之间的响应均匀性良好。像素桥结构将芯片温度漂移对像素输出的影响降低到约40 /spl mu/V/K,比单个微热计探测器提高了300倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信