{"title":"A lifetime model for piezoceramic actuators in adaptronic systems","authors":"D. Flaschentrager, J. Nuffer","doi":"10.1109/RAMS.2013.6517628","DOIUrl":null,"url":null,"abstract":"This work presents a lifetime model for piezoelectric actuators by combination of previous available information/expertise and tailored tests in order to save test time and costs. It is shown that the assumptions drawn from expertise comply with the experimental results. Therefore, it was possible to set up a lifetime model which uses linear interpolation between given data points to assess the lifetime at any combination of relative humidity and temperature within the range covered by the model. The lifetime model is applied to a selected piezoceramic multilayer actuator (Ceramtec SP 505 7×7×32.4). The results of this application are presented and discussed. In general, the application of this method allows a cheaper lifetime assessments of piezoceramic actuators in early development stages of adaptronic systems.","PeriodicalId":189714,"journal":{"name":"2013 Proceedings Annual Reliability and Maintainability Symposium (RAMS)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Proceedings Annual Reliability and Maintainability Symposium (RAMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RAMS.2013.6517628","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents a lifetime model for piezoelectric actuators by combination of previous available information/expertise and tailored tests in order to save test time and costs. It is shown that the assumptions drawn from expertise comply with the experimental results. Therefore, it was possible to set up a lifetime model which uses linear interpolation between given data points to assess the lifetime at any combination of relative humidity and temperature within the range covered by the model. The lifetime model is applied to a selected piezoceramic multilayer actuator (Ceramtec SP 505 7×7×32.4). The results of this application are presented and discussed. In general, the application of this method allows a cheaper lifetime assessments of piezoceramic actuators in early development stages of adaptronic systems.
自适应系统中压电陶瓷作动器的寿命模型
为了节省测试时间和成本,本工作结合了以前可用的信息/专业知识和量身定制的测试,提出了压电致动器的寿命模型。结果表明,专家提出的假设与实验结果一致。因此,有可能建立一个寿命模型,该模型使用给定数据点之间的线性插值来评估模型覆盖范围内相对湿度和温度的任何组合下的寿命。寿命模型应用于选定的压电陶瓷多层执行器(Ceramtec SP 505 7×7×32.4)。本文介绍并讨论了这一应用的结果。一般来说,应用这种方法可以在自适应系统的早期开发阶段对压电陶瓷作动器进行更便宜的寿命评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信