On the integration of a microdialysis-based /spl mu/TAS with calibration facility on a silicon-glass sandwich

A. Sprenkels, W. Olthuis, P. Bergveld
{"title":"On the integration of a microdialysis-based /spl mu/TAS with calibration facility on a silicon-glass sandwich","authors":"A. Sprenkels, W. Olthuis, P. Bergveld","doi":"10.1109/MMB.2000.893797","DOIUrl":null,"url":null,"abstract":"The integration is discussed of all parts of a microdialysis-based micro Total Analysis System or /spl mu/TAS. In particular a microdialysis probe, a potentiometric and amperometric ion- and enzyme sensor and a calibration dosing pump have been developed separately using different precision machining techniques. By modifying and adapting these parts they can be realized in one generic technology consisting of a stack of a silicon and a glass wafer. The silicon wafer contains the double lumen microdialysis probe connections, a dosing pump chamber with meander formed cavities containing the calibration solutions and small cavities for both the potentiometric and amperometric sensor. The glass wafer contains all the electrical contacts and wires for the sensors, the pump and Interconnections. Both wafers are anodically bonded to each other, yielding a hermetically sealed liquid handling system.","PeriodicalId":141999,"journal":{"name":"1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMB.2000.893797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The integration is discussed of all parts of a microdialysis-based micro Total Analysis System or /spl mu/TAS. In particular a microdialysis probe, a potentiometric and amperometric ion- and enzyme sensor and a calibration dosing pump have been developed separately using different precision machining techniques. By modifying and adapting these parts they can be realized in one generic technology consisting of a stack of a silicon and a glass wafer. The silicon wafer contains the double lumen microdialysis probe connections, a dosing pump chamber with meander formed cavities containing the calibration solutions and small cavities for both the potentiometric and amperometric sensor. The glass wafer contains all the electrical contacts and wires for the sensors, the pump and Interconnections. Both wafers are anodically bonded to each other, yielding a hermetically sealed liquid handling system.
基于微透析的/spl mu/TAS与硅-玻璃夹层校准设备的集成
讨论了基于微透析的微全分析系统(/spl mu/TAS)各部分的集成。特别是微透析探针,电位和安培离子和酶传感器和校准剂量泵已分别开发使用不同的精密加工技术。通过修改和调整这些部件,它们可以在一种由硅和玻璃晶圆堆叠组成的通用技术中实现。硅片包含双流明微透析探头连接,一个剂量泵腔,其弯曲形成的腔含有校准溶液,以及用于电位和安培传感器的小腔。玻璃晶圆片包含传感器、泵和互连的所有电触点和电线。两个晶圆彼此阳极结合,产生一个密封的液体处理系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信