Direct assessment of protection operation and nonviable transients

C. Singh, I. Hiskens
{"title":"Direct assessment of protection operation and nonviable transients","authors":"C. Singh, I. Hiskens","doi":"10.1109/PESS.2001.970034","DOIUrl":null,"url":null,"abstract":"Summary form only given as follows. The transients induced in power systems by a large disturbance can initiate unexpected events such as protection operation or converter misfiring. This paper proposes a direct technique for assessing the likelihood of such events. The approach is based on Lyapunov (energy) function methods, but with the critical energy redefined to take account of protection operating characteristics and viability constraints. Power systems have many protection devices and many constraints that must be monitored. The paper provides a method of identifying the subset of protection devices and/or viability constraints that are most vulnerable for any particular disturbance. Controlling UEP (unstable equilibrium point) ideas underlie the algorithm.","PeriodicalId":273578,"journal":{"name":"2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESS.2001.970034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Summary form only given as follows. The transients induced in power systems by a large disturbance can initiate unexpected events such as protection operation or converter misfiring. This paper proposes a direct technique for assessing the likelihood of such events. The approach is based on Lyapunov (energy) function methods, but with the critical energy redefined to take account of protection operating characteristics and viability constraints. Power systems have many protection devices and many constraints that must be monitored. The paper provides a method of identifying the subset of protection devices and/or viability constraints that are most vulnerable for any particular disturbance. Controlling UEP (unstable equilibrium point) ideas underlie the algorithm.
直接评估保护操作和不可行的瞬变
摘要形式只提供如下。大扰动引起的电力系统暂态会引起保护动作或变流器失燃等意外事件。本文提出了一种评估此类事件发生可能性的直接技术。该方法基于Lyapunov(能量)函数方法,但重新定义了临界能量,以考虑保护操作特性和生存能力约束。电力系统有许多保护装置和许多必须监测的约束。本文提供了一种方法来识别保护装置的子集和/或最容易受到任何特定干扰的生存能力限制。控制不稳定平衡点(UEP)思想是该算法的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信