{"title":"A study on corrosion resistance of ISO 5832-1 austenitic stainless steel used as orthopedic implant","authors":"Lilian N. M. Braguin, Caio V. Juvencio da Silva, Larissa O Berbel, I. Costa, M. Saiki","doi":"10.25061/IJAMB.V3I2.83","DOIUrl":null,"url":null,"abstract":"The ISO 5832-1 austenitic stainless steel used as biomaterial is largely applied in the area of orthopedics, especially in the manufacture of implants, such as temporary or permanent replacement of bone structures. The objective of this study was to evaluate the localized corrosion resistance of the ISO 5832-1 stainless steel used in orthopedic implants by electrochemical tests in two different solutions. The results of this study are of great interest to evaluate the corrosion of metallic implants that can result in the release of corrosion products into bodily fluids causing possible adverse biological reactions. The determination of the chemical elements in the composition of the ISO 5832-1 stainless steel was performed by neutron activation analysis (NAA). The samples for electrochemical tests were grinded with silicon carbide paper up to #4000 finishing, followed by mechanical polishing with diamond paste. The open circuit potential measurements and anodic polarization curves were obtained in solution of 0.90 wt. % of NaCl and of simulated body fluid (SBF). The results indicated that the ISO 5832-1 stainless steel presented a high resistance to crevice corrosion in simulated body fluid solution but high susceptibility to this form of corrosion in the chloride solution. \n ","PeriodicalId":103125,"journal":{"name":"International Journal of Advances in Medical Biotechnology - IJAMB","volume":"174 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advances in Medical Biotechnology - IJAMB","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25061/IJAMB.V3I2.83","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The ISO 5832-1 austenitic stainless steel used as biomaterial is largely applied in the area of orthopedics, especially in the manufacture of implants, such as temporary or permanent replacement of bone structures. The objective of this study was to evaluate the localized corrosion resistance of the ISO 5832-1 stainless steel used in orthopedic implants by electrochemical tests in two different solutions. The results of this study are of great interest to evaluate the corrosion of metallic implants that can result in the release of corrosion products into bodily fluids causing possible adverse biological reactions. The determination of the chemical elements in the composition of the ISO 5832-1 stainless steel was performed by neutron activation analysis (NAA). The samples for electrochemical tests were grinded with silicon carbide paper up to #4000 finishing, followed by mechanical polishing with diamond paste. The open circuit potential measurements and anodic polarization curves were obtained in solution of 0.90 wt. % of NaCl and of simulated body fluid (SBF). The results indicated that the ISO 5832-1 stainless steel presented a high resistance to crevice corrosion in simulated body fluid solution but high susceptibility to this form of corrosion in the chloride solution.  
骨科植入物用ISO 5832-1奥氏体不锈钢耐腐蚀性能的研究
ISO 5832-1奥氏体不锈钢作为生物材料广泛应用于骨科领域,特别是在植入物的制造中,如骨结构的临时或永久替代。本研究的目的是通过电化学测试在两种不同的溶液中评估用于骨科植入物的ISO 5832-1不锈钢的局部耐腐蚀性。本研究的结果对评估金属植入物的腐蚀具有重要意义,金属植入物可能导致腐蚀产物释放到体液中,从而引起可能的不良生物反应。采用中子活化分析法(NAA)测定了ISO 5832-1不锈钢成分中的化学元素。电化学试验样品用碳化硅纸研磨至4000度,然后用金刚石膏进行机械抛光。在0.90 wt. % NaCl溶液和模拟体液(SBF)溶液中获得了开路电位测量和阳极极化曲线。结果表明,ISO 5832-1不锈钢在模拟体液溶液中具有较高的抗缝隙腐蚀性能,但在氯化物溶液中对这种形式的腐蚀具有较高的敏感性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信