Y. Albayrak, Mehmet Dağli, Ozcan Asilkan, A. Yardimci, S. Bilgin, H. Uysal
{"title":"Image-processing based determination of kinesiologic parameters of spasticity patients","authors":"Y. Albayrak, Mehmet Dağli, Ozcan Asilkan, A. Yardimci, S. Bilgin, H. Uysal","doi":"10.1109/BIYOMUT.2014.7026387","DOIUrl":null,"url":null,"abstract":"In this study, it is aimed to obtain Patella T-Reflex kinesiologic parameters on spasticity patients by using image processing methods and thereby extracting objective data for the evaluation of spasticity patients. For this reason, the movement of Patella T-reflex response to knee joint was recorded with the help of a camera after three LED markers placed on the knee joint. For the correctness of the pattern of the movements, data were compared with two-axis goniometer of Biometric Ltd company and thereby it was shown that the reflex patterns are identical. Thereon, using the software we have developed, the Patella T-reflex kinesiologic parameters were calculated and data were obtained for objective evaluation of the Spasticity patients.","PeriodicalId":428610,"journal":{"name":"2014 18th National Biomedical Engineering Meeting","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 18th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2014.7026387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, it is aimed to obtain Patella T-Reflex kinesiologic parameters on spasticity patients by using image processing methods and thereby extracting objective data for the evaluation of spasticity patients. For this reason, the movement of Patella T-reflex response to knee joint was recorded with the help of a camera after three LED markers placed on the knee joint. For the correctness of the pattern of the movements, data were compared with two-axis goniometer of Biometric Ltd company and thereby it was shown that the reflex patterns are identical. Thereon, using the software we have developed, the Patella T-reflex kinesiologic parameters were calculated and data were obtained for objective evaluation of the Spasticity patients.