Multiple structural color hydrogel array integrated with microfluidic chip for biochemical sensor

Kenta Niibe, H. Onoe
{"title":"Multiple structural color hydrogel array integrated with microfluidic chip for biochemical sensor","authors":"Kenta Niibe, H. Onoe","doi":"10.1109/TRANSDUCERS.2017.7994027","DOIUrl":null,"url":null,"abstract":"This paper describes multiple structural color hydrogel array integrated with a two-layered microfluidic chip. The microfluidic chip can sense multiple physical/chemical targets (ex. concentration of chemicals and temperature) at the same time simply by eye-visible color changes of the arrayed stimuli-responsive structural color hydrogels in the top chambers. Sample solution was introduced in the bottom channel and react to the arrayed hydrogel via sandwiched porous membrane. We evaluated our device by measuring ethanol/water concentration and temperature, and confirmed the visible color changes of our sensor without any external equipment. We believe that our sensing device could be applied to a biochemical sensor or microanalytical chip for environmental monitoring sensor and wearable healthcare devices.","PeriodicalId":174774,"journal":{"name":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2017.7994027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper describes multiple structural color hydrogel array integrated with a two-layered microfluidic chip. The microfluidic chip can sense multiple physical/chemical targets (ex. concentration of chemicals and temperature) at the same time simply by eye-visible color changes of the arrayed stimuli-responsive structural color hydrogels in the top chambers. Sample solution was introduced in the bottom channel and react to the arrayed hydrogel via sandwiched porous membrane. We evaluated our device by measuring ethanol/water concentration and temperature, and confirmed the visible color changes of our sensor without any external equipment. We believe that our sensing device could be applied to a biochemical sensor or microanalytical chip for environmental monitoring sensor and wearable healthcare devices.
多结构彩色水凝胶阵列集成微流控芯片用于生化传感器
本文介绍了一种与双层微流控芯片集成的多结构彩色水凝胶阵列。微流控芯片只需通过顶部腔室中排列的刺激响应结构颜色水凝胶的肉眼可见颜色变化,即可同时感知多个物理/化学目标(例如化学物质的浓度和温度)。在底部通道中引入样品溶液,通过夹层多孔膜与排列的水凝胶发生反应。我们通过测量乙醇/水的浓度和温度来评估我们的装置,并在没有任何外部设备的情况下确认我们的传感器的可见颜色变化。我们相信我们的传感设备可以应用于生化传感器或微分析芯片,用于环境监测传感器和可穿戴医疗设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信