Jinho Kim, Geon-Min Park, Y. Kang, Byongjun Lee, E. Muljadi
{"title":"Voltage control of a wind power plant using the adaptive Q-V characteristic of DFIGs","authors":"Jinho Kim, Geon-Min Park, Y. Kang, Byongjun Lee, E. Muljadi","doi":"10.1109/PEMWA.2014.6912230","DOIUrl":null,"url":null,"abstract":"For the stable operation of a grid, the voltages of all buses in the grid should be maintained within an acceptable range. For a grid with high wind penetration, wind power plants (WPPs) are required to have the capability to maintain the voltage at the point of common coupling (PCC). Wind generators in a WPP produce the different active power due to the wake effects and consequently contain different reactive power availability. This paper proposes a voltage control scheme of a doubly-fed induction generator (DFIG)-based WPP using the adaptive reactive power-voltage (Q-V) characteristic of DFIGs. The WPP controller calculates a voltage error signal using a PI controller and sends it to each DFIG. From the voltage error signal, the DFIG injects the reactive power based on its adaptive Q-V characteristic, which depends on the available reactive power. The proposed scheme adjusts the Q-V characteristic depending on the operating condition of a DFIG. The proposed scheme enables the WPP to recover the PCC voltage to the nominal value within a short time after a disturbance by utilizing the reactive power capability of a WPP. The performance of the scheme was investigated for a 100 MW WPP consisting of 20 units of a 5 MW DFIG for a grid fault condition. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.","PeriodicalId":370712,"journal":{"name":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEMWA.2014.6912230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
For the stable operation of a grid, the voltages of all buses in the grid should be maintained within an acceptable range. For a grid with high wind penetration, wind power plants (WPPs) are required to have the capability to maintain the voltage at the point of common coupling (PCC). Wind generators in a WPP produce the different active power due to the wake effects and consequently contain different reactive power availability. This paper proposes a voltage control scheme of a doubly-fed induction generator (DFIG)-based WPP using the adaptive reactive power-voltage (Q-V) characteristic of DFIGs. The WPP controller calculates a voltage error signal using a PI controller and sends it to each DFIG. From the voltage error signal, the DFIG injects the reactive power based on its adaptive Q-V characteristic, which depends on the available reactive power. The proposed scheme adjusts the Q-V characteristic depending on the operating condition of a DFIG. The proposed scheme enables the WPP to recover the PCC voltage to the nominal value within a short time after a disturbance by utilizing the reactive power capability of a WPP. The performance of the scheme was investigated for a 100 MW WPP consisting of 20 units of a 5 MW DFIG for a grid fault condition. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.