W. Choi, S. Nelson, D.W. Ferwalt, R. Mongia, H. Shichijo, K. O. Kenneth
{"title":"Three-harmonic time-domain load-pull measurement system with the 40-GHz maximum third order harmonic frequency for nonlinear device characterization","authors":"W. Choi, S. Nelson, D.W. Ferwalt, R. Mongia, H. Shichijo, K. O. Kenneth","doi":"10.1109/ARFTG-2.2013.6737344","DOIUrl":null,"url":null,"abstract":"A three-harmonic time-domain load-pull measurement system, which operates up to 40 GHz for the highest harmonic, is demonstrated. The system uses a 50-GHz nonlinear vector network analyzer. The load generator is comprised of three synchronized signal generators and a harmonic combining network using cascaded broadband diplexers, as well as an optional mechanical tuner. Load-pull measurements are validated up to 16-GHz fundamental frequency by comparing the source impedance measured using a network analyzer and the Γopt measured using the load-pull measurement system. Measurements of a 0.25-μm GaN HEMT at 6-GHz fundamental frequency and a 0.5-μm InP HBT at 10-GHz fundamental frequency suggest that the power efficiency of amplifiers using the devices can be improved by 3-6% using the measurement results.","PeriodicalId":290319,"journal":{"name":"82nd ARFTG Microwave Measurement Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"82nd ARFTG Microwave Measurement Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG-2.2013.6737344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A three-harmonic time-domain load-pull measurement system, which operates up to 40 GHz for the highest harmonic, is demonstrated. The system uses a 50-GHz nonlinear vector network analyzer. The load generator is comprised of three synchronized signal generators and a harmonic combining network using cascaded broadband diplexers, as well as an optional mechanical tuner. Load-pull measurements are validated up to 16-GHz fundamental frequency by comparing the source impedance measured using a network analyzer and the Γopt measured using the load-pull measurement system. Measurements of a 0.25-μm GaN HEMT at 6-GHz fundamental frequency and a 0.5-μm InP HBT at 10-GHz fundamental frequency suggest that the power efficiency of amplifiers using the devices can be improved by 3-6% using the measurement results.