{"title":"Finger-force measurement-device for hand rehabilitation","authors":"S. Olandersson, H. Lundqvist, M. Bengtsson, M. Lundahl, A. Baerveldt, M. Hilliges","doi":"10.1109/ICORR.2005.1501069","DOIUrl":null,"url":null,"abstract":"The purpose was to develop an extension fingerforce measurement device, and investigate the intraindividual repeatability. The design of the measuring device allows single finger force and whole hand measurements, and the repeatability error on extension finger forces was measured, both on the whole hand, as well as on individual fingers. The tests showed that a repeatability error of less then 15 % can be achieved for single finger measurements and less then 21 % for whole hand measurements.","PeriodicalId":131431,"journal":{"name":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2005.1501069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

Abstract

The purpose was to develop an extension fingerforce measurement device, and investigate the intraindividual repeatability. The design of the measuring device allows single finger force and whole hand measurements, and the repeatability error on extension finger forces was measured, both on the whole hand, as well as on individual fingers. The tests showed that a repeatability error of less then 15 % can be achieved for single finger measurements and less then 21 % for whole hand measurements.
用于手部康复的指力测量装置
目的是开发一种扩展指力测量装置,并研究个体内可重复性。测量装置的设计允许单指力和全手力的测量,并测量了整个手和单个手指上伸指力的重复性误差。实验表明,单指测量的重复性误差小于15%,全手测量的重复性误差小于21%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信