{"title":"Avoiding AC/DC grid interaction in MMC based MTDC systems","authors":"A. G. Endegnanew, Gilbert Bergna-Diaz, K. Uhlen","doi":"10.1109/EVER.2017.7935937","DOIUrl":null,"url":null,"abstract":"In this paper, the interaction between ac and dc grids is studied for two types of MMC control structures; conventional and non-conventional control structures. Linear analysis methods that are based mode shapes and participation factors are used to identify dynamic interaction in a hybrid ac-dc power system. The analysis uses as a test system a three terminal Modular Multilevel Converter (MMC) based Multi-terminal High Voltage DC (MTDC) grid connecting three multi-machine asynchronous ac grids. The results show that there is some dynamic interaction between ac and dc grids under conventional MMC converter control structure, while the non-conventional MMC converter control structure decouples the ac and dc side of the MMC converter, thus avoiding interaction between the ac and dc grids.","PeriodicalId":395329,"journal":{"name":"2017 Twelfth International Conference on Ecological Vehicles and Renewable Energies (EVER)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Twelfth International Conference on Ecological Vehicles and Renewable Energies (EVER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EVER.2017.7935937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
In this paper, the interaction between ac and dc grids is studied for two types of MMC control structures; conventional and non-conventional control structures. Linear analysis methods that are based mode shapes and participation factors are used to identify dynamic interaction in a hybrid ac-dc power system. The analysis uses as a test system a three terminal Modular Multilevel Converter (MMC) based Multi-terminal High Voltage DC (MTDC) grid connecting three multi-machine asynchronous ac grids. The results show that there is some dynamic interaction between ac and dc grids under conventional MMC converter control structure, while the non-conventional MMC converter control structure decouples the ac and dc side of the MMC converter, thus avoiding interaction between the ac and dc grids.