Practical considerations for single-pole-trip line-protection schemes

F. Calero, D. Hou
{"title":"Practical considerations for single-pole-trip line-protection schemes","authors":"F. Calero, D. Hou","doi":"10.1109/cpre.2005.1430423","DOIUrl":null,"url":null,"abstract":"This paper discusses some practical aspects of implementing single-pole tripping schemes in transmission-line protection. Implementation and techniques will vary in the design of protective relaying systems that implement single-pole trip (SPT), as well as in the philosophy of the users applying these devices; however, the intent is to discuss issues that need to be considered for SPT systems. We present a quick review of the benefits and implementation of SPT, emphasizing the benefits for power system stability with a relatively minor incremental cost compared to three-pole trip (3PT) systems for EHV and many HV transmission systems. We also discuss specific aspects of implementing single-pole-tripping in line-protective relaying schemes. In addition, we discuss using a faulted-phase selection algorithm, some reclosing scheme philosophy, and the greater flexibility that improved communication channels give to SPT systems. We analyze the open-pole period of an SPT system to gain some insight into the behavior of the measured quantities and protective relaying elements.","PeriodicalId":395312,"journal":{"name":"58th Annual Conference for Protective Relay Engineers, 2005.","volume":"124 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"58th Annual Conference for Protective Relay Engineers, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/cpre.2005.1430423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper discusses some practical aspects of implementing single-pole tripping schemes in transmission-line protection. Implementation and techniques will vary in the design of protective relaying systems that implement single-pole trip (SPT), as well as in the philosophy of the users applying these devices; however, the intent is to discuss issues that need to be considered for SPT systems. We present a quick review of the benefits and implementation of SPT, emphasizing the benefits for power system stability with a relatively minor incremental cost compared to three-pole trip (3PT) systems for EHV and many HV transmission systems. We also discuss specific aspects of implementing single-pole-tripping in line-protective relaying schemes. In addition, we discuss using a faulted-phase selection algorithm, some reclosing scheme philosophy, and the greater flexibility that improved communication channels give to SPT systems. We analyze the open-pole period of an SPT system to gain some insight into the behavior of the measured quantities and protective relaying elements.
单极脱扣线路保护方案的实际考虑
本文讨论了在输电在线保护中实施单极跳闸方案的一些实际问题。实施和技术将在实施单极跳闸(SPT)的保护继电器系统的设计中有所不同,以及在应用这些设备的用户的理念中;然而,本文的目的是讨论SPT系统需要考虑的问题。我们快速回顾了SPT的优点和实施,强调与超高压和许多高压输电系统的三极脱扣(3PT)系统相比,SPT在电力系统稳定性方面的优势相对较小。我们还讨论了在线路保护继电器方案中实现单极跳闸的具体方面。此外,我们还讨论了使用故障相位选择算法,一些重合闸方案的原理,以及改进的通信通道给SPT系统带来的更大的灵活性。我们分析了SPT系统的开极周期,以了解被测量和保护继电器元件的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信