Performance Evaluation of FACTS Placement Methods for Available Transfer Capability Enhancement in a Deregulated Power Networks

B. O. Adewolu, A. Saha
{"title":"Performance Evaluation of FACTS Placement Methods for Available Transfer Capability Enhancement in a Deregulated Power Networks","authors":"B. O. Adewolu, A. Saha","doi":"10.1109/SAUPEC/RobMech/PRASA48453.2020.9041146","DOIUrl":null,"url":null,"abstract":"This study investigates the performance of FACTS device based on different methods of placements for available transfer capability enhancement (ATC). Total real power loss, real power performance index, real power loss sensitivity with respect to line reactance, power transfer distribution factor (PTDF), line thermal limitation, available transfer capability (ATC) value, and least bus voltage magnitude are the placement methods considered. Each of these methods is used independently for location of Thyristor Controlled Series Compensator (TCSC) device for ATC enhancement. The study has been conducted on standard IEEE 30 bus test systems for comparison. The enhanced ATC values, bus voltage magnitudes and real power loss are then used in assessment of performance of TCSC with respect to locations. Disparities in enhancement ranges between 2% and 85% were achieved while real power loss minimization of up to 25% was obtained based on different placement methods.","PeriodicalId":215514,"journal":{"name":"2020 International SAUPEC/RobMech/PRASA Conference","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International SAUPEC/RobMech/PRASA Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAUPEC/RobMech/PRASA48453.2020.9041146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This study investigates the performance of FACTS device based on different methods of placements for available transfer capability enhancement (ATC). Total real power loss, real power performance index, real power loss sensitivity with respect to line reactance, power transfer distribution factor (PTDF), line thermal limitation, available transfer capability (ATC) value, and least bus voltage magnitude are the placement methods considered. Each of these methods is used independently for location of Thyristor Controlled Series Compensator (TCSC) device for ATC enhancement. The study has been conducted on standard IEEE 30 bus test systems for comparison. The enhanced ATC values, bus voltage magnitudes and real power loss are then used in assessment of performance of TCSC with respect to locations. Disparities in enhancement ranges between 2% and 85% were achieved while real power loss minimization of up to 25% was obtained based on different placement methods.
解除管制电网中增强可用传输能力的FACTS放置方法的性能评价
本研究探讨了基于不同放置方式的FACTS装置的性能,以提高可用转移能力(ATC)。实际总功率损耗、实际功率性能指标、实际功率损耗对线路电抗的灵敏度、功率传输分配系数(PTDF)、线路热限制、可用传输能力(ATC)值和最小母线电压幅值是考虑的放置方法。每一种方法都独立用于晶闸管控制串联补偿器(TCSC)器件的ATC增强定位。本研究已在标准IEEE 30总线测试系统上进行比较。增强的ATC值、母线电压幅值和实际功率损耗随后用于评估TCSC相对于位置的性能。增强范围在2%到85%之间,而基于不同的放置方法,实际功率损失最小化高达25%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信